My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:39:37 PM
Creation date
6/23/2020 6:52:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> TAIT DEC12 201 <br /> HEALTH <br /> WLEAK DETECTOR <br /> TESTING <br /> » ti <br /> 6 <br /> Facility Name : Unified Grocers,Inc. Test Date: 11/18/2014 <br /> Location <br /> Tested: 1990 Piccoli Road Technician : Victor Guerrero <br /> Stockton <br /> Cal iforni a <br /> 8017001-UT <br /> 95215 ICC#: <br /> Test I nformation <br /> Product Diesel <br /> Manufacturer FE-Petro <br /> Model STP-MLD-D <br /> New Leak Detector(Yes/No) No <br /> Serial Number MH1393 <br /> Electronic LD(Yes/No) No <br /> Calibrated Test Leak Rate: (189 Yes <br /> mil/min @ 10 PSI)(Yes/No) <br /> Check Valve Holding PSI Yes <br /> Resiliency (Bleed Back MIL) 115 MIL <br /> Slow Flow Metering PSI/(N/A) 10 PSI <br /> Turbine Shut Down Electronic LD NA <br /> (Yes/No/NA) <br /> Slow Flow At Nozzle Yes <br /> (Yes/No/NA) <br /> Opening Time(Seconds) 3 SEC. <br /> Pass/Fail Pass <br /> This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the <br /> equipment manufacturers procedures and limitations and the results as listed are to my knowledge true and correct.The <br /> leak detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br /> Technician Signature: Date : 11/18/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.