Laserfiche WebLink
0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sugov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility United Grocers, Inc. Facility 1990 N. P'iccoli, Stockton Inspection Nov 21, 2012 <br />Name: <br />Address: Date: <br />VIOLATIONS <br /># I <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />On Site Records (continued) <br />204 CCR 2715(c) Designated operator monthly inspection: (1) alarms not documented; (2-4) spill containers, UDCs, and sumps <br />if necessary) not inspected; 5 required test dates not checked or noted; 6 employee training not verified <br />205 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br />206 CCR 2715(f) Designated operator employee training: (1) not performed; (2) not current for at least one employee on site; <br />3 tonot k <br />207 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />Observations <br />301 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(M1) <br />303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br />304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (M1) <br />305 CCR 2636(%1) Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an (Mt) <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 CCR 2631(a) Primary containment is not product tight <br />307 HSC 25291(a)(2) Secondary containment for UST system is not tight <br />308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />309 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (1112) <br />310 HSC 25291(e) Water in 2° containment not removed, analyzed & properly disposed of <br />311 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (11111) <br />312 CCR 2635(b) No spill container or overfill prevention system installed (M2) <br />313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (11112) <br />the spill container empty <br />314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (11012) <br />315 HSC 25299(0(2) ITampering with or disabling leak detection devices or alarms <br />316 CCR 2631.1(a) UST system is not compatible with the substance stored <br />317 HSC 25298(a) ---iillegally abandoned UST system <br />AS 1702 (2003-2004) HSC 25290.1 (installed between 07101/03 and 06130/04) . . <br />YPH Systems HSC 25290.1 installed on or after 07/01/04 <br />401 <br />CCR 2631.1 <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d) <br />for a UST system installed after July 1, 2004, were not submitted <br />402 <br />HSC 25290.1(c)(1) <br />HSC 25290.2(c)(1) <br />Primary containment not liquid or vapor tight <br />403 <br />HSC 25290.1(c)(2) <br />HSC 25290.2(c)(2) <br />Secondary containment not liquid or vapor tight <br />404 <br />HSC 25290.1(c)(3) <br />HSC 25290.2(c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />405 <br />HSC 25290.1(d) <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />liquid or vapor from the primary containment into the secondary containment <br />406 <br />HSC 25290.1(e) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not'maintained <br />407 <br />HSC 25290.16) <br />HSC 25290.2 t .4 ,. <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />ressur6testapproved by ,SWRCB;- 3 test method dt2l6d eequivalent to 1 or 2 by the SWRCB <br />Emergency Generator Systems <br />501 <br />CCR 2636(/)(6) <br />I Emergency generator monitoring system not checked daily or log not kept if no leak detector (M1) <br />502 <br />HSC 25281.5(b)(3) <br />Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br />USTs Ina Vault <br />601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br />603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 HSC 25283.5(a)(5) UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />Non -Pressurized Piping <br />701 CCR 2643(d) Daily monitoring of suction piping (pre -January 1, 1984) not performed (M7) <br />- 7• a �• �+i 1 <br />EHD 23.02 Rev 04/19/12 / / Page 2 UST INSPECTION REPORT <br />