Laserfiche WebLink
VIECEIVED <br />SW CB J nuary 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containmen �rr et <br />printouts from tests (if applicable), should be provided to the facility owner/operator for sub h %Yency!.!W <br />1. FACILITY INFORMATION Facility ID: 01 ERAS � <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: TAIT Environmental Services <br />Technician Conducting Test: Wes Morrison <br />Credentials': ❑x CSLB Contractor ® ICC Service Tech. ❑ SWRCB Tank Tester ❑ Other (Specify) <br />License Number(s): A B ASB C-10 HAZ, 588098 8250125 <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ❑x Hydrostatic ❑Vacuum ❑Other <br />Facility Name: Unified Grocers, Inc Date of Testing: 11-21-2016 <br />Equipment Resolution: 1/16" <br />Facility Address: 1990 Piccoli Rd. Stockton CA 95215 <br />Facility Contact: Todd George I Phone: (209) 931-7431 <br />Date Local Agency Was Notified of Testing: 11/11/2016 <br />T1 Diesel <br />Name of Local Agency Inspector (afpresent during testing): Vicky McCartney <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: TAIT Environmental Services <br />Technician Conducting Test: Wes Morrison <br />Credentials': ❑x CSLB Contractor ® ICC Service Tech. ❑ SWRCB Tank Tester ❑ Other (Specify) <br />License Number(s): A B ASB C-10 HAZ, 588098 8250125 <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ❑x Hydrostatic ❑Vacuum ❑Other <br />Test Equipment Used: Tape Measure <br />Equipment Resolution: 1/16" <br />Identify Spill Bucket (By TankI <br />Number, Stored Product, etc.) <br />T1 Diesel <br />2 <br />3 <br />4 <br />Bucket Installation Type: <br />❑x Direct Bury <br />❑Contained in Sump <br />❑On Top of AST <br />[I Direct Bury <br />[]Contained in Sump <br />El On Top of AST <br />[]Direct Bury <br />❑Contained in Sump <br />❑On Top of AST <br />❑Direct Bury <br />❑Contained in Sump <br />❑On Topof AST <br />Bucket Diameter: <br />11" <br />Bucket Depth: <br />13.5" <br />Wait time between applying <br />vacuum/water and start of test: <br />15 min <br />Test Start Time (Ti): <br />9:15am <br />Initial Reading (Ri): <br />11.25" <br />Test End Time (TF): <br />10:15am <br />Final Reading (RF): <br />11.25" <br />Test Duration (TF — TI): <br />1 hr <br />Change in Reading (RF - Ri): <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />0 <br />Test Result: <br />Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />All test water was left on site. <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: <br />11-21-2016 <br />State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />