My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2014-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2020 12:18:05 PM
Creation date
6/23/2020 6:53:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2018
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2014-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H1=Gr-1VED <br />FEB 16 2016 <br />TA I T ENVIRONMENTAL <br />4=e I TU ncpq RTMENT <br />Test Date: 02-01-2016 <br />LEAK DETECTOR TESTING <br />Facility ID: 01 Client Name: Unified Grocers, Inc <br />Street Address: 1990 Piccoli Rd. Technician: Victor Guerrero <br />City: Stockton ICC #: 8017001 <br />Zip Code / State: 95215 / CA Manufacturer Cert #: <br />Test Information <br />Product <br />Diesel <br />Manufacturer <br />Vaporless <br />Model <br />Hi Flo <br />New Leak Detector <br />Yes/No <br />No <br />Serial Number <br />NA <br />Electronic LD <br />(Yes/No) <br />No <br />Calibrated Test Leak <br />Rate: (189 mil/min <br />Yes <br />10 PSI) (Yes/No <br />Check Valve Holding <br />PSI <br />42 psi <br />Resiliency <br />(Bleed Back MIL) <br />250 mil <br />Slow Flow <br />Metering PSI / N/A <br />21 psi <br />Turbine Shut Down <br />Electronic LD <br />NA <br />Yes/No/NA <br />Slow Flow At Nozzle <br />Yes/No/NA <br />Yes <br />Opening Time <br />4 Seconds <br />(Seconds) <br />Pass/Fail <br />Pass <br />I his letter certities that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The leak detector test pass/fail is determined using a low flow threshold trip <br />rate of 3 gph at 10 PSI. <br />Technician Signature: ice, <br />Date: 02-01-2016 <br />CA lira 588098 , AZ dicx 095984 ,r NV tic* 0049666 1 TX hO CR0000041 <br />