My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PICCOLI
>
1990
>
2300 - Underground Storage Tank Program
>
PR0231820
>
COMPLIANCE INFO_2014-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2020 12:18:05 PM
Creation date
6/23/2020 6:53:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2018
RECORD_ID
PR0231820
PE
2361
FACILITY_ID
FA0003826
FACILITY_NAME
Supervalu
STREET_NUMBER
1990
Direction
N
STREET_NAME
PICCOLI
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10121001
CURRENT_STATUS
01
SITE_LOCATION
1990 N PICCOLI RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231820_1990 N PICCOLI_2014-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 7 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.ora/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Unified Grocers Inc. <br />Facility Phone: <br />209 931-9440 <br />Date: <br />November 23 2015 <br />Facility Address: <br />1990 N PICCOLI RD STOCKTON CA 95215 <br />CERS ID: <br />10181455 <br />Inspection Contact: <br />Mike Young <br />Title: <br />Supervisor <br />Phone: <br />209 <br />931-7431 <br />Inspection Type: <br />ROUTINE INSPECTION <br />- Operatinq Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />N Inspection Z Photos Z Samples <br />I Consent Given By: <br />I Mike Young, Supervisor <br />Service Technician Onsite <br />Victor Guerrero <br />Exp. Date: <br />06/09/2017 <br />Designated Operator: <br />Michael Young <br />Exp. Date: <br />Service Technician Manufacturer's Training <br />Veeder-Root 06/28/17-1 VMI Tester, 11/09/17; Incon Level 4 04/23/17 <br />CCR =California coca of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 <br />HSC 25284 <br />No permit to operate <br />❑ V <br />❑ R o COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V <br />❑ R ❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />■ V <br />■ R o COS <br />104 <br />CCR 2711 <br />UST Operating Permit Application for Facility and Tank information not submitted or current <br />■ V <br />❑ R ❑ COS <br />105 <br />HSC 25286(c) <br />Current BOE number not submitted <br />o V <br />o R ❑ COS <br />106 <br />CCR 2632 <br />Monitoring and response plans not current or approved by the EHD <br />■ V <br />■ R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V <br />❑ R ❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V <br />o R ❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V <br />❑ R ❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V <br />❑ R ❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />o V <br />❑ R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V <br />❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V <br />❑ R ❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V <br />o R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />■ V <br />❑ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />❑ R ❑ COS <br />117 <br />HSC 25292.5 <br />Failed to conduct ELD testing on a system located within 1000' of a public well <br />❑ V <br />❑ R ❑ COS <br />118 <br />HSC 25292.5 <br />Failed to repair and retest system due to failed ELD test <br />o V <br />❑ R o COS <br />119 <br />CCR 2644.1(a)(5) <br />Failed to submit ELD test results within 60 days <br />❑ V <br />❑ R ❑ COS <br />120 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V <br />❑ R o COS <br />121 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V <br />❑ R ❑ COS <br />122 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />o V <br />o R o COS <br />123 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />❑ V <br />❑ R o COS <br />124 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />o V <br />❑ R o COS <br />Received by <br />(initiaq: '-- <br />Inspector: <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />Date: <br />11/23/2015 <br />Page 1 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.