My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
907
>
2300 - Underground Storage Tank Program
>
PR0231871
>
COMPLIANCE INFO_1986-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:04:06 PM
Creation date
6/23/2020 6:53:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1997
RECORD_ID
PR0231871
PE
2361
FACILITY_ID
FA0003968
FACILITY_NAME
AT&T California - UE046
STREET_NUMBER
907
Direction
W
STREET_NAME
LINCOLN
STREET_TYPE
Rd
City
Stockton
Zip
95207
APN
077-470-07
CURRENT_STATUS
01
SITE_LOCATION
907 W Lincoln Rd
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231871_907 W LINCOLN_1986-1997.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Total Coinment markets h" quality <br /> environ ental protection pro ucts_fo.r . <br /> your secondary containment <br /> Bulkhead Fittings Dis,-,+ser Sumps and Pans Liquid-tight Sump/Risers Double-Wall underground Storage <br /> Tanks <br /> Guide Specifications <br /> Short Form Structural Integrity: The outer secondary contain- <br /> The contractor shall provide the Enviroflext Double-Wall ment system shall be of such design and materials to <br /> piping system, as manufactured by Total Containment, have sufficient strength to withstand the maximum <br /> Inc. Both the primary and secondary piping systems shall underground burial loads and tested in accordance <br /> be installed and integrity tested in accordance with the with AASHTO M294. The flexible inner primary pip- <br /> manufacturer's published installation instructions. ing system shall be capable of withstanding liquid <br /> pressure five times greater than the designed operat- <br /> Long Form ing pressures. <br /> Design:The Double-Wall Piping System shall consist of Integrity Testing: The outer secondary containment <br /> a UL/ULC listed flexible inner primary pipe contained systems shall undergo an air pressure hold test (3 to <br /> within a ULC listed flexible outer containment pipe,each 5 psi) after installation and before the final backfill. <br /> making connection within a series of surface access The flexible inner primary piping system shall be sub- <br /> containment chambers.All piping runs shall be continu- ject to 60 psi air pressure hold test prior to final back- <br /> ous, whereby there shall be no fittings or piping con- fill. <br /> nections, for either the primary or secondary contain- Monitoring Capability:_ The design of the secondary <br /> ment pipe which are not visible or accessible from containment system shall permit any leak in the pri- <br /> aboveground. The secondary containment piping shall mary piping system to be detected by a leak detection <br /> be sized to allow complete removal of the primary piping system. <br /> without excavation. The secondary containment system Access Chambers: Surface access containment <br /> shall provide watertight containment of the tank's piping chambers shall be located at the tank containing the <br /> and its associated fittings,and the shear valve assembly tank's submersible pump and under each above- <br /> located below each aboveground fuel dispenser unit. ground fuel dispenser. These access chambers shall <br /> Product Compatibility: All the components of the meet the following requirements: <br /> Double-Wall Piping System shall be compatible with the 1, Provide product-tight tank or island connection. <br /> products to be stored. 2. Provide product-tight pipe and conduit exits. <br /> Corrosion Resistance: All components of the Double- 3. Provide sufficient strength to keep out <br /> Wall Piping System shall be made of non-corrosive surrounding backfill material. <br /> materials, or if metallic, such as the fittings and cou- 4. Made of non-corrosive, product compatible and <br /> plings, isolated from corrosion causing agents. dielectric materials. <br /> i <br /> j <br /> h <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.