Laserfiche WebLink
Monitoring System Certification <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work.A copy of this torm Must be provided o tne tank system owner opera or.The <br /> owner opera or must su mi a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility: Pacific Bell Telephone Co.dba AT&T California GEO PAR#UE046 <br /> Address: 907 LINCOLN RD. City: STOCKTON Zi : 95207 <br /> Facility Contact Person: CONNIE MITCHELL E.S.M. Contact Phone No: 209-474-4022 <br /> Make/Model of Monitoring System:VEEDER ROOT TLS-350 Service Date: 06/17/2008 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate speck equipment inspected/serviced: <br /> Tank ID:#UE0460002 Tank ID: <br /> ®In-Tank Gauging Probe Model:847390-104 ❑In-Tank Gauging Probe Model: <br /> ®Annular Space or Vault Sensor Model:794390420 ❑Annular Space or Vault Sensor Model: <br /> ®Piping Sump/Trench Sensor(s) Model:794380-208 ❑Piping Sump/Trench Sensor(s) Model: <br /> ®Fill Sump Sensor(s) Model:794380-208 ❑Fill Sump Sensor(s) Model: <br /> ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ®Tank Overfill/High Level Sensor Model:790091-001 ❑Tank Overfill/High Level Sensor Model: <br /> ❑Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) <br /> TanklD: TanklD: <br /> ❑In-Tank Gauging Probe Model: ❑In-Tank Gauging Probe Model: <br /> ❑Annular Space or Vault Sensor Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s) Model: ❑Piping Sump/Trench Sensor(s) Model: <br /> ❑Fill Sump Sensor(s) Model: ❑Fill Sump Sensor(s) Model: <br /> ❑Mechanical Line Leak Detector Model: ❑Mechanical Line Leak Detector Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High Level Sensor Model: ❑Tank Overfill/High Level Sensor Model: <br /> ❑Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) <br /> Dispenser ID: Dispenser lD: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: ❑Dispenser Containment Sensor(s) Model: <br /> ❑Shear Valve(s) ❑Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification-i certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers'guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify <br /> that this information is correct and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of <br /> generating such reports,1 have also attached a copy of the report; (check all that apply): <br /> ®System s ®Alarm history report <br /> Technician Name(Print): MICHAEL L. STRAWN, 11 Sign lure: <br /> Certification No: VEEDER ROOT-A31215 License No: 588098 <br /> Testing Company Name:TAIT ENVIRONMENTAL Phone No: (714)560-8222 <br /> SERVICES <br /> Page 1 of 4 <br />