My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AD ART
>
3330
>
2300 - Underground Storage Tank Program
>
PR0231901
>
COMPLIANCE INFO_2001-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:23 AM
Creation date
6/23/2020 6:53:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2004
RECORD_ID
PR0231901
PE
2361
FACILITY_ID
FA0003825
FACILITY_NAME
CALIFORNIA HIGHWAY PATROL #265*
STREET_NUMBER
3330
Direction
N
STREET_NAME
AD ART
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
3330 N AD ART RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231901_3330 N AD ART_2001-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ID ID ID <br /> # DESCRIPTION&MANUFACTURER * # DESCRIPTION&MANUFACTURER * # DESCRIPTION&MANUFACTURER <br /> 0 1 DOUBLE-WALL JACKETED TANK 23 CONDUIT EXPANSION OZ(OPTIONAL) 42 OVERHEAD RETRACTOR CNI,POMECO 06100 <br /> v 3 STORAGE TANK (COUNTYERWEIGHT)& <br /> 24 CONDUIT SEALS OZ-INSTALL PER'90 NEC 06102(SPRING BALANCE) <br /> 2 NPT TANK FITTINGS (6)4"AND(2) 1 112" w <br /> �m 91 (D a 25 SHEET METAL TRIM FIELD FABRICATE&ATTACH 43 JUNCTION BOX OZ-EXPLOSION PROOF <br /> r we � 3 FRP CONTAINMENT 13"TO 43" TO SUMP RISER <br /> SL COLLAR <br /> Cs N 26 2"TANK VENT LINE 2"FIBERGLASS REINFORCED EQUIPMENT AT OIL HOUSE <br /> ro w N 4 SUMP RISER SYSTEM MATCH COLLAR I.D. PLASTIC PIPE <br /> ® 44 INVENTORY&LEAK VEEDOR-ROOT TLS 350 <br /> CDCEO 5 36"FILL MANWAY CNI,POMECO 06311&06511 27 1-1/2"VAPOR RETURN ENVIROFLEX 1-1/2"PP1501 ALARM PANEL WITH PRINTER <br /> FLEXIBLE PIPING W/ <br /> 6 36"TURBINE MANWAY CNI,POMECO 06110-36Wi FLEXIBLE SECONDARY 45 (DELETED) <br /> CONTAINMENT <br /> 7 INTERSTITIAL CNI 46 MOTOR CONTROL BOX RED JACKET <br /> MONITOR ACCESS 28 STRIKER PLATE STEEL PLATE,OR TANK <br /> BOTTOM PROTECTOR- 47 ELEC.WIREWAYS SQUARE D <br /> 8 SUBMERSIBLE TURBINE RED JACKET-1.5 HP, POMECO 06140 <br /> 314 HP,1/2 HP 48 MOTOR STARTER RED JACKET <br /> 29 INTERSTITIAL LEAK 2"SCH.40 STEEL PIPE RISER <br /> C7 ---I-n 9 TANK LEVEL PROBE EMCO WHEATON-STD. MONITOR RISER W/2"x Z"x 3/4"T&PLUG 49 (DELETED) <br /> y D C EMCO WHEATON-STLS. FOR FUTURE <br /> r Z m 50 EMERGENCY SHUT-OFF SQUARE D <br /> -T1 �r 10 FILL ADAPTER EMCO WHEATON, DPW 633T 30 4"PLUG PLUG CENTER NPT FITTING <br /> O co 51 REMOTE AUDIBLE ALARM FIELD LOCATE <br /> 10A FILL CAP EMCO WHEATON,OPW 634TT 31 PROBE CAP PROVIDE 4"CAP IF PROBE IS <br /> D C/) <br /> � NOT INSTALLED 52 REMOTE VISUAL ALARM FIELD LOCATE <br /> 11 VAPOR ADAPTER EMCO WHEATON,DPW 1611 AV <br /> m 32 FLEX CONNECTOR UL.TELEFLEX 53 CONDUIT SEAL OZ <br /> = 11A VAPOR CAP EMCO WHEATON,OPW 1711T UL.FLEXEVER <br /> 54 ELECTRICAL CONDUIT PVC COATED STEEL PER 1993 <br /> DZ 12 OVERFILL PREVENTION OPW 61SO 33 2"-90 DEG.ELBOW SCH.40 GALVANIZED STEEL NEC <br /> VALVE&DROP TUBE <br /> -.0 34 PIPE BRACE W/BOLTS,NUTS,STL PLATE, 55 ELEC.SUB PANEL SQUARE D-SIZE FOR LOAD, <br /> y 13 EXTRACTOR VENT VALVE UNIVERSAL,DPW 233VM VIBRATION ISOLATORS VOLTAGE <br /> DC7 13A BALL FLOAT VENT VALVE DPW 53V SERIES 35 SUPPLY EXIT SCH.40 STEEL PIPE WITH 56 PRESSURE/VACUUM OPW 523LP <br /> O 2"STEEL UNION VENT VALVE <br /> r <br /> 14 LIQUID LEAK SENSOR EMCO WHEATON <br /> 15 1-1/2"PRIMARY FLEXIBLE ENVIROFLEX 1-1/2"PP1501 EQUIPMENT AT DISPENSER ISLAND <br /> PIPING <br /> 36 FUEL DISPENSERS WAYNE,GILBARCO <br /> 16 FLEXIBLE INCLUDED WITH <br /> SECONDARY PIPING PRIMARY PIPING 37 BREAKAWAY COUPLING DPW 66 SERIES(NONVAPOR) <br /> 8 6601(VAPOR) <br /> C (/1 17 TEST CLAMP FITTING <br /> C 0 D 38 PRODUCT SHEAR VALVE EMCO,DPW 10 SERIES <br /> x <br /> _s O m r 18 4"RISER PIPE AMERICAN MADE SCH.40 38A VAPOR SHEAR VALVE EMCO,DPW 60V SERIES <br /> =3 Z M B.P.OR STAINLESS STL. <br /> O n ®p 39 SPILL CONTAINMENT BRAVO CONTAINMENT BOX <br /> = <br /> v _u _u 19 CLASS-DIV1 J-BOX OZ/GEDNEY AT SENSORS& MODEL TO MATCH DISP.BASE <br /> 9: LEVEL PROBE <br /> m 39A FUEL ISLAND FORM RED-E-FORM <br /> ZI 20 CLASS-DTVI J-BOX OZ-SEAL UNUSED OPENINGS <br /> 40 UNLEADED GAS NOZZLE EMCO,OPW 11VF,i i 1V,211V <br /> (BALANCE)&11VA1(ASSIST) <br /> 21 CLASSI-DIV1 J-BOX OZ-6"MAX.BELOW MANWAY <br /> LID 40A DIESEL NOZZLE OHB((1'DIESEL)3/4")&7H, <br /> 22 CONDUIT TO PANELS PVC COATED RIGID,INSTALL *MANUFACTURERS LISTED,OR EQUAL,ARE <br /> CONDUCTORS PER'90 NEC 41 U.L.FUEL HOSE 12'GOODYEAR MAXXIM ACCEPTABLE. <br /> PREMIER COAXIAL EQUIPMENT SUBMITTALS MUST BE APROVED <br /> BY STATE IN WRITING. <br /> 41A DIESEL FUEL HOSE 16'DUPONT THERMOID <br /> PUMPFLEX SERIES 1481-12 <br /> l <br />
The URL can be used to link to this page
Your browser does not support the video tag.