Laserfiche WebLink
FA0003825 PR0231901 SCO01 06/28/2017 <br />EHD 23-01 Rev. 09/22/16 Page I of 6 Underground Storage Tank Program OIR <br />9171 9690 0935 01314339 10 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: wvvw.s1gov.or-q/ehd <br />'-- <br />d 1, to <br />N <br />Facility Name: Facility Phone: <br />CALIFORNIA HIGHWAY PATROL #265* (209) 943-8666 <br />Date: <br />June 28, 2017 <br />Facility Address: <br />3330 N AD ART RD, STOCKTON, CA 95215 <br />CERS ID: <br />10181453 <br />Inspection Contact: <br />Jim Murray <br />Title: <br />Auto Tech <br />Phone: <br />(209) 938-4820 <br />Inspection Type: Program: <br />ROUTINE INSPECTION - Operating Permit 2361 - LIST FACILITY <br />Consent For: Consent Given By: <br />0 Inspection N Photos Z Sam les Jim Murray, Auto Tech <br />Service Technician Onsite: Exp. Date: <br />Hamzah Abdallah 09/17/2018 <br />Designated Operator: <br />Robert Carr <br />Exp. Date: <br />03/22/2019 <br />Service Technician Manufacturer's Training: <br />VMI, 12/13/16; VR, 10/25/18 <br />CCR = California Code of Regulations HSC - Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation <br />COS = Corrected on site during inspection <br />A: <br />& <br />101 <br />HSC 25284 <br />No permit to operate <br />m V <br />o R <br />o COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V <br />o R <br />Ei COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />o V <br />o R <br />o COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V <br />o R <br />o COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />o V <br />o R <br />o COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />o V <br />Ei R <br />c COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />m V <br />o R <br />o COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V <br />o R <br />o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />m V <br />m R <br />o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />ii V <br />o R <br />o COS <br />ill <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />m V <br />m R <br />o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />m V <br />n R <br />o COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />Ei V <br />o R <br />Ei COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />o V <br />o R <br />Ei COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />o V <br />o R <br />o COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />o V <br />o R <br />o COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />o V <br />o R <br />o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />o V <br />c R <br />o COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />o V <br />o R <br />c COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />o V <br />o R <br />o COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />o V <br />o R <br />o COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />o V <br />o R <br />C1 COS <br />gq- <br />201CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />m V <br />o R <br />o COS <br />202 CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />ii V <br />o R <br />o COS <br />203 CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />o V <br />o R <br />o COS <br />FA0003825 PR0231901 SCO01 06/28/2017 <br />EHD 23-01 Rev. 09/22/16 Page I of 6 Underground Storage Tank Program OIR <br />9171 9690 0935 01314339 10 <br />