Laserfiche WebLink
RECEIVE[ <br />MONITORING SYSTEM CERTIFICATION FEB 17 2016 <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code Tj <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must ENT <br />monitoring, system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CNP Stocton <br />Site Address: 3330 N. Ad Art Rd. <br />Facility Contact Person: Linh <br />Make/Model of Monitoring System: TLS -350 <br />B. Inventory of Equipment Tested/Certified <br />r1l. 1, t6n n..n..n...datn hn to iedinute S recon anninmant insn"ted/wrvir0d! <br />Bldg. No.: <br />City: Stockton Zip: 96215 <br />_ Contact Phone No.: (209) 943-8666 <br />Date of Testing/Servicing: 1/1912016 <br />Tank ID: 87 <br />Tank ID: <br />® In -Tank Gauging Probe. <br />Model: VR -Mag <br />® In -Tank Gauging Probe, <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: VR 420 <br />® Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: VR 208 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: VR 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: FE PETRO <br />® Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />® In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 112 <br />Dispenser ID: <br />® Dispenser Containment Sensor(s). <br />Model: VR 208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: - <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Piot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Robert S. Carr Signature: t�s,.//,� .g.. E,2_� <br />Certification No.: 8340716 License. No.: 872234 <br />Testing Company Natne: Rumex Construction Corp Phone No.: (559) 271-3300 <br />Testing Company Address: 3755 W. Gettysburg Ave., Fresno, CA 93722 Date of Testing/Servicing: 1/19/2016 <br />Page 1 of 3 <br />Rev (2/08) <br />