Laserfiche WebLink
MONIING SYSTEM CERTI ATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION /TEST DATE: October 28. 2013 <br />A1. FACILITY <br />Name Countryside 76 <br />Address 14971 N. Highway 88, Lodi, CA 95240 <br />Phone # 209-368-5380 <br />Contact Rupinder Padda <br />A2. OWNER <br />Name Rupinder Padda <br />Address 18662 North Hwy 88, Lockeford, CA 95237 <br />Phone # 209-727-3064 <br />Contact Rupinder Padda <br />A3. C U P A <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />l31: TANKS <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Tank #1 (Product): Gasoline - 87 <br />❑ In -Tank Gauging Probe Model: <br />■ Annular Space or Vault Sensor Model: 0794390-420 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />October 23, 2013 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Aris Cacapit <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # <br />916-373-1166 <br />B. <br />INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br />l31: TANKS <br />Tank #1 (Product): Gasoline - 87 <br />❑ In -Tank Gauging Probe Model: <br />■ Annular Space or Vault Sensor Model: 0794390-420 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />Tank #2 (Product): Gasoline - 91 <br />❑ In -Tank Gauging Probe <br />❑ Annular Space or Vault Sensor <br />■ Piping Sump I Trench Sensor(s) <br />❑ Fill Sump Sensor(s) <br />❑ Mechanical Line Leak Detector <br />❑ Electronic Line Leak Detector <br />❑ Tank Overfill / High -Level Sensor <br />❑ Other (specify equipment in Section E) <br />Model: <br />Model: <br />Model: 0794380-208 <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Tank #3 (Product): Diesel <br />❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />Tank #4 (Product): <br />❑ In -Tank Gauging Probe <br />❑ Annular Space or Vault Sensor <br />❑ Piping Sump I Trench Sensor(s) <br />❑ Fill Sump Sensor(s) <br />❑ Mechanical Line Leak Detector <br />❑ Electronic Line Leak Detector <br />❑ Tank Overfill / High -Level Sensor <br />❑ Other (specify equipment in Section E) <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />Model: <br />62: <br />DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) <br />■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Model: 0794380-208 <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />1 _ . \ f \� WALTON <br />Signature: all O` W ENGINEERING, INC. <br />Technician / Cert #: Jessie Wadkins / B35391 5307886 -UT Date: October 28, 2013 <br />