Laserfiche WebLink
• <br />0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s* og v.orq/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Countryside Liquor & Gas <br />rY q <br />VIOLATIONS <br />Facility <br />14971 N. Hwy 88 Lodi, CA 95240 <br />Y <br />Inspection <br />Inspection <br />Apr 17, 2013 <br />Name: <br />M <br />I Code Section <br />Date: <br />Facility <br />Rupinder Padda <br />File Review <br />Ftle <br />owner) <br />814-5576 <br />Contact: <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 X HSC 25292.2 <br />Inspection <br />Type: x Routine X Monitoring System <br />Certification ❑ Installation ❑ Complaint - ID#: ! Other: <br />(Authority HSC 25289) <br />Consentfor. XInspection XSampling XPhotos <br />Ru finder Padda owner <br />Granted by: h Title: <br />MonitoringVdRt TLS -350 <br />Panel: l:eeer-Root <br />Pa <br />Piping <br />System: <br />1Pressurized L! Suction !1 Gravity <br />overfill <br />Prevention: DQ Mechanical Audible/visual <br />UST <br />4 <br />- <br />5 <br />- <br />6 <br />-- <br />-- <br />----------------------------- <br />Annual spill containment testing not performed <br />-------------- <br />----- --- <br />113 CCR 2715(a) <br />- - - - - - <br />-----Pr- <br />-Pr- <br />87 -octane <br />91 -octane <br />diesel <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 <br />Permit to repair UST system not obtained <br />118 HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Designated Alex Jabbari <br />Operator. <br />ate: : <br />Date: <br />10-6-14 <br />Violations: I; M1 -Release Detection xM2-Release Prevention ❑ M3 - Both <br />On Site Service <br />Zane Nimmo <br />ICC Exp. <br />Manufacturer's <br />6-23-13 vmi 1-29-15, ff 8-11-13, yr 9-24-13 <br />Technician: <br />Date: <br />Training: <br />Inspector Received y: Title: <br />Aris Cacapit (209) 468-3453 <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />VIOLATIONS <br /># <br />I C1 <br />I C2 <br />M <br />I Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 <br />No permit to operate <br />102 HSC 25404.5 <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 X HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 X CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 X CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 x CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 X CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) <br />Annual line leak detector test not performed (Ml) <br />111 HSC 25284.2 <br />Annual spill containment testing not performed <br />112 CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 <br />Permit to repair UST system not obtained <br />118 HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) <br />Permit to close UST system not obtained <br />On Site Records <br />201 x CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6%years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 x CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M7) <br />was not recorded; (e) escaped secondary containment, not cleaned ul after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector Received y: Title: <br />Aris Cacapit (209) 468-3453 <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />