My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:06:52 PM
Creation date
6/23/2020 6:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.oro/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Eagle. Arco AM PM #5450 Facility 1617 W. Fremont St., Stockton Inspection Aug2, 2013 <br />Name: Address: Date: g <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br />Class II violations: (117, 305, 310) <br />117. The C1 87 master fill sump sensor was replaced on June 30, 2013 and a permit was not obtained <br />from the EHD. Emergency repairs relating to UST system monitoring and release detection may be <br />performed by a properly licensed, trained, and certified contractor pursuant to the EHD's policy and a <br />permit obtained within one business day from the EHD. All other repairs must have a permit submitted <br />to and approved by the EHD prior to beginning work. Immediately obtain a permit from the EHD for the <br />sensor replacement. A "Failure to Obtain a Permit" penalty applies. <br />305. The 87 siphon fill sump sensor failed to activate an audible and visual alarm when tested to <br />ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to <br />activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />The sensor was replaced and retested during the inspection. <br />310. A small amount of dark liquid was observed in the UDC 3/4 sump. If water could enter into the <br />secondary containment by precipitation or infiltration, it must be removed and disposed of properly. The <br />liquid was removed at the time of inspection. Ensure that the UDC sumps are maintained free of liquid. <br />Complete and submit a copy of the Return to Compliance Certification to the EHD by September 22, <br />2013, along with a statement documenting the corrective actions that have been or will be taken for each <br />violation, and any supporting paperwork. <br />Note: The position sensor on the 87 master STP sump sensor was not shutting down the turbine. The <br />sensor was replaced at the time of inspection. <br />Provided: Return to Compliance Certification form <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE AB E NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTIO AWTI14CA1E CURRENT HOURLY RATE. <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation, C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e)Biennial <br />tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M7) <br />Other Violations <br />999 <br />Other: <br />See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br />Class II violations: (117, 305, 310) <br />117. The C1 87 master fill sump sensor was replaced on June 30, 2013 and a permit was not obtained <br />from the EHD. Emergency repairs relating to UST system monitoring and release detection may be <br />performed by a properly licensed, trained, and certified contractor pursuant to the EHD's policy and a <br />permit obtained within one business day from the EHD. All other repairs must have a permit submitted <br />to and approved by the EHD prior to beginning work. Immediately obtain a permit from the EHD for the <br />sensor replacement. A "Failure to Obtain a Permit" penalty applies. <br />305. The 87 siphon fill sump sensor failed to activate an audible and visual alarm when tested to <br />ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to <br />activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br />The sensor was replaced and retested during the inspection. <br />310. A small amount of dark liquid was observed in the UDC 3/4 sump. If water could enter into the <br />secondary containment by precipitation or infiltration, it must be removed and disposed of properly. The <br />liquid was removed at the time of inspection. Ensure that the UDC sumps are maintained free of liquid. <br />Complete and submit a copy of the Return to Compliance Certification to the EHD by September 22, <br />2013, along with a statement documenting the corrective actions that have been or will be taken for each <br />violation, and any supporting paperwork. <br />Note: The position sensor on the 87 master STP sump sensor was not shutting down the turbine. The <br />sensor was replaced at the time of inspection. <br />Provided: Return to Compliance Certification form <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE AB E NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTIO AWTI14CA1E CURRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.