Laserfiche WebLink
9255517888 Line 12:48:29 08-12-2013 3/4 <br />91 VETTIfa-RYAN INC. <br />tob # 20-591407.1 <br />SWRCB, January 2002 Page 2 of 2 <br />G 1' 1► 1►i 1' *111111111 CI ]! <br />Test Method Developed By: <br />Tank Manufacturer <br />Other (specify) <br />Industry Standard <br />Professional Engineer <br />Test Method Used: <br />Pressure <br />Other (specify) <br />Vacuum <br />Ilvdrostatic <br />Test Equipment Used: <br />Incon <br />Equipment Resolution: <br />0.0001 <br />m ua <br />t "aa <br />Sum <br />81-1 <br />Sump <br />Sump <br />_ -- <br /># <br />Sump Diameter: <br />48" <br />_ <br />Sump Depth: <br />51" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />27„ <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />21„ <br />Condition of sump prior to testing; <br />Good <br />Portion of Sump Tested (1) <br />2"Above Piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />Yes <br />No <br />Yes <br />No NA <br />Yes <br />No <br />NA <br />Yes <br />No <br />NA <br />Turbine shutdown response time <br />N/A <br />Is system programmed for fail-safe <br />shutdown?* <br />Yes <br />No <br />Yes <br />No NA <br />Yes <br />No <br />NA <br />Yes <br />No <br />NA <br />Was fail-safe verified to be <br />o erational?* <br />Yes <br />No <br />Yes <br />No NA <br />Yes <br />No <br />NA <br />Yes <br />No <br />NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />10min <br />Test Start Time: <br />9:45 <br />Initial Reading (Ri): <br />4.7424 <br />Test End Time: <br />10:00 <br />Final Reading (Rf) <br />4.7422 <br />Test duration: <br />15min <br />Change in Reading (Rf-Ri): <br />-0.0002 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Tests Results.:. <br />X..::.Pass, , , Fail, :;.:: <br />; : Pass, <br />1Fael .:: <br />bass <br />. ` <br />Fail; <br />Pass.::: Fail <br />Was sensor removed for testing? <br />No NA <br />Yes <br />No NA <br />Yes <br />No <br />NA <br />Yes <br />No <br />NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes <br />No <br />it 1 <br />Yes <br />No NA <br />Yes <br />No <br />NA <br />Yes <br />No <br />NA <br />.1 <br />Comments - (include information on repairs made prior to testing, and recommend follow-up for failed tests) <br />(1) If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Received Time Aug.12. 2013 12:41PM No.3856 <br />