My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:06:52 PM
Creation date
6/23/2020 6:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />I <br />Station # Arco 5450 -Date 8/22 2013 <br />•.I 1 1. U01 I VATIVA <br />Test Information <br />This letter certifies that the annual leak detector tests were perfonned at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The mechanical leak test detector test pass/fail is determined using a low <br />flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Geftler-Ryan Inc. <br />Technician. Joey Mesa <br />Signature <br />Lic# <br />1 <br />2 <br />3 <br />4 <br />5 <br />Product <br />87 <br />91 <br />Manufacturer <br />VR <br />VR <br />Model <br />848480 <br />848480 <br />Full Operating Pressure (psi) <br />29 <br />28 <br />Line Bleed Back (ml) <br />NA <br />NA <br />Trip Time (see) <br />NA <br />NA <br />Metering Pressure (psi) <br />NA <br />NA <br />F/E Holding Pressure (psi) <br />21 <br />20 <br />Test Leak Rate (ml/min)(gph) <br />189ml <br />189ml <br />PASS or FAIL <br />P <br />P <br />This letter certifies that the annual leak detector tests were perfonned at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The mechanical leak test detector test pass/fail is determined using a low <br />flow threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor Geftler-Ryan Inc. <br />Technician. Joey Mesa <br />Signature <br />Lic# <br />
The URL can be used to link to this page
Your browser does not support the video tag.