My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:06:52 PM
Creation date
6/23/2020 6:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9255517888 Line 10:57:50 09-09-2013 10/12 <br />State Water Resources ConA&oard Page 1 of 2 <br />Home •>,> Ust -->> Leak Prevention >t Lg113 -* Vendors <br />USTPI'O�ra..n, .....Z'G i1�........................................................................................................................ <br />Issue Date: December 7, 2001 <br />Revision Date: Aprif 8, 2011 <br />Veeder-Root <br />TLS -350, 36OR Series, TLS -450 Series, Red Jacket ProMax with <br />Discriminating Interstitial Sensor 794380-343, Micro Sensor 794380-344 <br />INTERSTITIAL DETECTOR (LIQUID -PHASE) <br />Detector: <br />Output type: <br />qualitative, discriminating (794380-343), non -discriminating (794380- <br />diesel** <br />344) <br />Sampling frequency: <br />continuous <br />Operating principle: <br />optical sensor and conductivity (794380-343), optical sensor (794380- <br />Fall time (min) <br />op) <br />Test Results: <br />*California requires annual certification of all leak detection equipment. The certification of discriminating <br />sensors should include functional testing of both water and product detection capabilities. <br />Model 794380-343: This sensor can only respond to liquid directly in contact with the detection element, and <br />Is unable to detect a product release floating on an existing pool of water whose height exceeds the level of <br />the detection element. <br />Discriminating Interstitial Sensor <br />794380-343 <br />unleaded gasoline <br />diesel** <br />water <br />Detection time (min) <br /><1 <br /><1 <br /><1 <br />Fall time (min) <br /><1 <br /><1 <br /><1 <br />Lower detection limit (in) <br /><0.1 <br />71 <br />71 <br />Micro Sensor 794380-344*** <br />unleaded <br />ggLsoline <br />diesel <br />water <br />E85 <br />Used <br />Oil <br />Detection time (min) <br /><1 <br /><1 <br /><1 <br /><1 <br /><1 <br />Fall time (min) <br /><1 <br /><1 <br /><1 <br /><1 <br /><1 <br />Lower detection limit (in) <br /><0.1 <br /><0.1 <br /><0,1 <br /><0.1 <br /><0.125 <br />**Evaluations determined these sensors' responses to the liquids shown above. Siodiesel blends 136-820 meeting <br />ASTM D7467 and biodiesel 8100 meeting ASTM D6751 would also produce an alarm if the sensor threshold is <br />exceeded. Responses to these fuels were not determined, but would be expected to be very similar to the diesel <br />responses. <br />***This sensor is identified as an interstitial sensor, but will function properly in other containment areas such as <br />containment sumps, contained risers and other contained enclosures. This sensor must be installed at the lowest point <br />of the containment enclosure to insure early detection of liquids. <br />Specificity Results: <br />Evaluator claims both 794380-343 and 794380-344sensors will respond in any liquid after the sensor threshold is <br />http://www.waterboards.ca.gov/ust/leak2reventionAgl13/vendors/veeder root u.shtmi 9/9/2013 <br />