My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/26/2023 11:46:22 AM
Creation date
6/23/2020 6:53:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231923_1617 W FREMONT_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
361
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br />3_ Pinina Leak Detection Monitorina Eauipment <br />MoniiorQg Method <br />Manufacturer <br />Model <br />Monitoring Frequency <br />Sump leak sensors connected to <br />Veeder Root <br />794380-208 <br />Continuous <br />continuous monitoring system <br />794380-344 <br />Specify type: <br />Veeder Root <br />794380-208 <br />Continuous <br />❑ Discriminating <br />Continuous <br />® Non -discriminating <br />❑ Mechanical line leak detectors with <br />programmed leak threshold of three <br />❑ Daily <br />Every pumping cycle <br />lions per hour <br />❑ Other: <br />❑ No under -dispenser containment <br />Electronic line leak detectors with <br />Red Jacket <br />CPT <br />programmed leak threshold of: <br />Every pumping cycle <br />❑ 0.1 gph ❑0.2 gph 03 gph <br />Line integrity testing by: <br />❑ Electronic line leak detector is <br />equipped to conduct line tightness <br />❑ Annually <br />testing <br />❑ Other: <br />❑ Third party testing <br />® Not required <br />❑ Other (Specify): <br />4. Dispenser Leak Detection Monitorina Eauipment <br />Monitoring Method <br />Manufacturer <br />Model <br />Monitoring Frequency <br />❑ Mechanical float in dispenser <br />Continuous <br />containment <br />Electronic leak sensor in dispenser <br />Veeder Root <br />794380-208 <br />containment: <br />Continuous <br />F1 Discriminating <br />® Non -discriminating <br />❑ Daily <br />❑ Visual inspection <br />❑ Other: <br />❑ No under -dispenser containment <br />❑ Other (specify): <br />5. Posarve Snutaown <br />❑ Individual dispenser shutdown will occur whenever release_ is sensed in under -dispenser containment I <br />® Automatic pump shut off will occur whenever: <br />® Release is sensed in turbine sump <br />® Release is sensed in primary piping <br />® Release is sensed at dispenser <br />® Monitoring system is disconnected or fails in any way (fail safe) <br />❑ Other (specify): <br />6. Secondary Containment Testin <br />❑ Secondary containment is not tested <br />® In the State of California, secondary containment systems installed on or after January 1, 2001, shall be tested upon installation, <br />six months after installation, and every 36 months thereafter. Secondary containment systems installed prior to January 1, 2001, <br />shall be tested by January 1, 2003, and every 36 months thereafter. <br />7. Annual Equipment CertificationtTesting <br />® Annually <br />❑ Other (specify): <br />K <br />