Laserfiche WebLink
EXIST. VEEDER-ROOT <br />TLS -350 MONITOR <br />STEEL PLATE <br />PAINT TO <br />SYSTEM <br />DESCRIPTION MANUFACTURER MODL+(t' PART JW <br />142" DIAMETER MULTI -PORT SPILL CONTAINMENT MANHOLE & FRAME <br />PL=109.50' <br />EXIST. <br />65218-EVR- 164042RT052 <br />T. E. <br />DPW <br />61VSA-EVR <br />61VSA-1020-EVR <br />EXIST. FILL SUMP (TYP.) INSTALL NEW <br />1 2 3 4 OVERFILL ALARM W/ <br />5 6 8 11 ACKNOWLEDGMENT EXIST. VENT <br />_ SWITCH 70 RISERS 7 13 <br />(3) EXIST. U.G. n y e d ! e <br />FUEL STORAGE i ? ? F 1 <br />TANKS ®. PLANTER <br />EXIST. INTERSTITIAL <br />CANOPY 1 UNL NL. SUP t MONITOR (TYP D I.D. SIGN <br />1 (12K) (12K) (12K) <br />O.1 (J /) <br />II,Oa 11 �/ m <br />® 1 1 / <br />EXIST. EXIST. P.I.C. UNIT 1 1 TURBINE <br />E.S.O. (TYP. OF 2) 1 1 EXIST. CANOPY SUMP (TYP. <br />1 11 COLUMN EXIST. TANK SLAB / <br />EXIST. 1 1 EXIST. DRIVE SLAB <br />DISPENSERSON ISLAND 1. <br />(TYP.) <br />1 1 401.39 <br />R= - GaIA . <br />EX51PROPCH <br />� SIDEWALK � <br />_ EXIST. CONCREtE <br />REEM�N.r AvC"N�� 2D <br />2a a 4a 60' <br />17.03 <br />EXAP51. PROACH <br />GRAPHIC SCALE <br />PL=285.82' <br />1 - - <br />' t A6tt� <br />y PLANTER %A' <br />A <br />I - <br />INSTALLATION NOTES: <br />BEFORE START OF SAW CUTTING, REMEASURE TO CONFIRM THAT EXISTING MANHOLE FRAME IS NOT COMPATIBLE <br />WITH NEW MANHOLE LID. IF LID IS COMPATIBLE, DO NOT CUT UNTIL FIELD ENGINEER HAS CONFIRMED A NEED TO <br />REPLACE MANHOLE FRAME. <br />(Z)CONTRACTOR TO SAW CUT 6• X 6• MINIMUM SECTIONS OF EXISTING TANK SLAB AT EACH MANWAY AS SHOWN. <br />Q CONTRACTOR TO REMOVE EXISTING FILL SPILL BUCKETS. REMOVE EXISTING DROP TUBE FLAPPER VALVE (IF ANY), <br />AND ANY NON-EVR BALL FLOATS. <br />0 CONTRACTOR TO INSTALL NEW EVR RISER ADAPTERS. <br />® CONTRACTOR TO INSTALL. NEW 5 GALLON SPILL CONTAINMENT BUCKETS AND MANHOLE W/ FRAME AT EACH TANK <br />FILL. EVR VR -102-8 COMPLIANT. INSTALL NEW WATER SHIELD AND RISER SUPPORTS AT EACH FILL SUMP. <br />0 CONTRACTOR TO INSTALL NEW FILL DROP TUBE AND BALL FLOATS AT EACH TANK. EVR VR -102-8 COMPUw. <br />©CONTRACTOR TO INSTALL NEW RISER COMPONENTS AT EXISTING TANK GAUGE RISERS. FIELD VERIFY EXACT RISER <br />LOCATION. EVR VR -102-8 COMPUANT. <br />7O CONTRACTOR TO INSTALL NEW PRESSURE VACUUM VENT VALVE AS NEEDED, AT EACH GASOLINE VENT RISER. <br />EVR VR -102-8 COMPLIANT. <br />® CONTRACTOR TO PATCH ALL REMOVED CONCRETE TO MATCH EXISTING. <br />0 NOT USED. <br />10 IN :NEW VEEOER-ROOT OVERFILL A ACKNOWLEDGMENT; H AND NEW AUTOMATIC TANK <br />G -1F: MDT EXIT ' <br />11 - CONTRACTOR TO INSTALL NEW RIS OFFSET AT VAPOR RISER TO OBTAIN 16" O.C. FlLL AND <br />VAPOR RISERS. (WHEN EXISTING IS LESS THAN 16" O.C. ONLY) <br />EQUIPMENT LIST <br />E <br />STEEL PLATE <br />PAINT TO <br />" <br />DESCRIPTION MANUFACTURER MODL+(t' PART JW <br />142" DIAMETER MULTI -PORT SPILL CONTAINMENT MANHOLE & FRAME <br />POMECO <br />521 <br />65218-EVR- 164042RT052 <br />PHASE I BRONZE SWIVEL ADAPTER <br />DPW <br />61VSA-EVR <br />61VSA-1020-EVR <br />PHASE I VAPOR TOP SEAL CAP <br />OPW <br />17117-EVR <br />1711T-7085 <br />PHASE I VAPOR RECOVERY SPILL CONTAINMENT. 5 GALLON <br />CAST IRON, W/DRAIN VALVE PLUG <br />OPW <br />1SC-2100 <br />TSC -2100 VAPOR <br />c C: N O <br />FACE SEAL ADAPTER, PHASE I RISER, ATG RISER, & FILL RISER <br />OPW <br />FSA -400 <br />FSA -400 <br />I n O •% O <br />FILL BRONZE SWIVEL ADAPTER <br />OPW <br />61SALP-EVR <br />61SALP-1020-EVR <br />I E '— S.. M <br />I <br />FILL TOP SEAL CAP <br />OPW <br />634TT-EVR <br />63477-7085 <br />�•> n <br />FILL SPILL CONTAINMENT. 5 GALLON CAST IRON,ppW <br />1SC-2100 <br />15C-2100 FILL W/ GRAIN <br />+� a 0 -i- O <br />W/EVR DRAIN VALVE <br />(n <br />O O J <br />O <br />JACK SCREW ASSEMBLY IN FILL BUCKET <br />OPW <br />61JSK-4400-EVR <br />61JSK-4400-EVR <br />0) <br />STRAIGHT FILL DROP TUBE <br />OPW <br />61T <br />61T-7368-� <br />Q <br />E <br />FITTING, EXTRACTOR, TEE, 4"X4"X3"X3" <br />DOW <br />233 <br />233VM-4433 <br />•� <br />Q = L <br />TANK GAUGE PORT COMPONENTS (CAP & RING KIT) <br />MORRISON BROS. <br />305XPA110OAKEVR <br />305XPA1100AKEVR ' <br />0_ 3 <br />n <br />n <br />THREADED PRESSURE VENT CAP <br />OPW <br />623V <br />623V <br />+, 0 0 N <br />U <br />NOT USED <br />,a�I �0U <br />(n oa C0 <br />3" X 12" BALLFLOAT <br />OPW <br />53VML-3120 <br />53VML-3120 <br />O <br />WATER SHIELD <br />DPW <br />' v!L Din0 <br />- <br />RISER SUPPORT <br />OPW <br />RB -1600 <br />I <br />OVERFILL ALARM WITH HORN/STROBE 120VAC, <br />VEEDER-ROOT <br />VR -790091-001 ALARM <br />VR -790095-001 SWITCHN <br />Q M <br />Of <br />ACKNOWLEDGE SWITCH. & AUTOMATIC TANK GAUGE <br />VR -847390-10X TANK GAUGE <br />CD <br />� <br />01 <br />Cl- <br />Q <br />m U <br />v <br />402" MANI <br />1 <br />FILL CAP <br />FILL 5 GALLON <br />BUCKET (W/ <br />DRAIN VALVE) <br />JACK SCREW - <br />ASSEMBLY <br />0 <br />FACE SEAL <br />DROP TUBE <br />10 <br />PLATE <br />PHASE I CAP <br />PHASE I <br />PHASE 1 5 <br />GALLON <br />BUCKET (NO <br />DRAIN VALVE) <br />ATG CAP AND <br />RING KR <br />FACE SEAL <br />ADAPTER <br />EXTRACTOR <br />FITTING <br />(BEYOND) <br />BALL FLOAT <br />VALVE LOCATED <br />AT 952 <br />CAPACITY <br />SET ALARM <br />O 902 <br />STAGE I VAPOR RECOVERY & <br />FILL DETAIL (GASOLINE) <br />NO. <br />Underground Service Alert _ <br />- PROPRIETARY ARD CONFlDPJ9TIAL INPORMATION NO. DATI <br />THIS DLER <br />Call: TOLL FREE AND "IAT ANO ITS CUEAM THE NT AHAS NBEEN FURNISHED IN HEREIN RELATING �ROENCC FOR <br />THE PRNATE USE OF AUTHORIZED PERSONNEL. NO PART HEREOF SHALL BE <br />1 _ 8 00FUELING 8 COPIED. DUPUCATEO. OGRGSUTED, DISCLOSED OR MADE AVNLABLE TO <br />OTHERS OR USED TO ANY EXTENT WHATSOEVER EXCEPT AS EXPRESSLY <br />227-2600 POSITIONS AUTHORIZED W WRING BY FRED FIEDLER AND ASSOCMTES AND ITS CUENT. <br />ANY PERSON, FIRM OR CORPORATION RECEIVING THIS DOCUMENT, HOWEVER <br />OBTAINED, SHAD. BY VIRTUE HEREOF BE DEEMED TO HAVE AGREED TO THE <br />(9 NOZZLES 8 FOREGOING RESTRICTIONS. <br />TWO WORKING DAYS BEFORE YOU DIG <br />ACKNOWLEDGE <br />SWITCH <br />6" 0 BOLLARD <br />- <br />FILLW/ CONC. <br />(TYP. 2) <br />ESO <br />WP ENCL. <br />RECEPT, <br />4"x4" STEEL — <br />POST PAINT TO <br />MATCH SITE <br />CONDITIONS <br />SEAL -OFF — <br />1" RGS CONDUIT <br />FINISHED <br />GRADE <br />ED <br />s <br />4"x4" <br />JUNCTION <br />BOX <br />21 OVERFILL ALARM N.T.S. <br />4'xV <br />STEE <br />PIPE <br />EXTR <br />FTRII <br />11 <br />BALL <br />LOCA <br />APA <br />15 <br />20"x14"x1/4" <br />!` <br />STEEL PLATE <br />PAINT TO <br />0 <br />MATCH SITE <br />IL <br />CONDRIUN' <br />Q <br />J <br />Q <br />Lo <br />o � <br />V <br />I <br />z <br />V <br />Q <br />M 5 a <br />J <br />EL <br />I azw <br />N I- o <br />I_ <br />o i <br />Z L, <br />(n <br />O O J <br />r- :a <br />0 <br />LAJU <br />Z_ <br />FOOTING <br />�/ LL_ Z <br />IL <br />O <br />Q <br />LLJ <br />V) <br />n <br />n <br />,a�I �0U <br />r <br />G � <br />< <br />K <br />U_" <br />' v!L Din0 <br />I -J^ 4 <br />W WW q <br />D <br />J 3Z w3:i <br />W I, I D <br />NJLL4W <br />31 TYPICAL TURBINE ELEVATION N.T.S. <br />BP WEST COAST PRODUCTS, LLC MASTER REVISIONS <br />BID <br />CONST. <br />AS -BUILT <br />08/20/03 IEra IwDby I <br />05450 <br />I name <br />TK 1-1 <br />