Laserfiche WebLink
May-N-08 w a am I"rom-ustuer Inc TVIOU-111011 I-010 r uv4tuvu r-L�o <br /> Results of Testing/Servilding <br /> Software Version Installed: <br /> Complete the following checkWt. <br /> Z) Yes 0 No' Is the audiblel'alarm operational? <br /> El yds 0 No* 15 the visual a[arm operationa]5- <br /> El ye5 El Now Were all sens6rs visually inspected, tbrictionally tested,and confirmed oPerational? <br /> • Yes 0 Now Were ail sensg'rs installed at lowest point o <br /> I Cs-econdary containment and positioned$0 <br /> not interfc:re wl ith their proper operation? <br /> • Ycs 0 No* i alarms arei. relayed to a remote monitoring station, is all communications equipment (e.g' moderr <br /> operational? <br /> 0 N, /A <br /> E) Yes 0 Now For presstirfze�-piping systems, does Me turbine automatically shut down if the piping secondary containmen <br /> 0 N/A monitoring sy$iem detects a leak, fails to operate,or is electrically disconnected? If Yes: which sensors initiat, <br /> positive shut- wn? (Check all Mar apply) 0 SumplTrench Sensors, Q Dispenser Containment Sensors, <br /> Yes 0 No Did you con Positive shut-down due to leaks and sensor faffure/disconnection? Q yes; Q No. <br /> FOt tank syst�ms that utilize the monitoring system 4s the primary tank overfill <br /> 'aming device (i.e. nc <br /> C) N/A mechanical ov�rfill prevention valve is i4st011ed), is the overfill warning alum visible and audible at the tank <br /> fill point(s)an-operating properly? If so,at what percent of tank capacity does the alarm Digger? <br /> 0 Yes* 13 No Was any monit"ritig equipment replac 7 If yes, dentifY specific sensors,probes,or % <br /> other equipment replaced <br /> and list the maln1facturer name and model for all replacment parts in Section E below. <br /> es* Q No Was liquid fou inside any secondazy containment systems designed as dry 4ysrcmsj (C:heck all thaf <br /> y Q Pmduct; 13 Zter. If yes,describe causes in Section B,below. �;P_P_1y) <br /> Q Now Was monijoring system set-up revieweTto-ensure proper settings?Attac I set up reports. <br /> FUC3Yy'1SS ftori-int equipment OPerationaJ per manufacturees specifications? <br /> In Section E below,describe how�tnd when thme dericien ics were or will be currectca. <br /> E. Comments: <br /> flnoe <br /> 113 M <br />