My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:24 PM
Creation date
6/23/2020 6:54:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1617\PR0231923\UST RETROFIT PLAN 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> SWRCB,January 2002 Page_6_of—7- <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑ Pressure ❑Vacuum ® Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution:+i-0.002" <br /> Fill Sump#87 MAIN Fill Sump#87 Fill Sump#91 Fill Sump# <br /> MANIFOLD <br /> Sump Diameter: 42" 42" 42" <br /> Sump Depth: 58" 59" 61" <br /> Height from Tank Top to Top of N/A N/A NIA <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 28" 31" 31" <br /> Electrical Penetration: <br /> Condition of sump prior to DIRTY DIRTY DIRTY <br /> testing: <br /> Portion of Sump Tested 2"ABOVE 2"ABOVE 2"ABOVE <br /> PENETRATION PENETRATION PENETRATION <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Wait time between applying <br /> pressure/vacuum/water and 30 MIN 30 MIN VISUAL FAIL <br /> starting test: <br /> Test Start Time: 11:22 1:38 <br /> Initial Reading(Rj): 4.7063" 5.6529" <br /> Test End Time: 11:37 1:53 <br /> Final Reading(RF): 4.7062" 5.6493" <br /> Test Duration: 15 MIN 15 MIN <br /> Chane in Reading(RF-RI): -0.00011, -0.0036" <br /> Pass/Fai I Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: ®Pass ❑ Fail ❑Pass ED Fail ❑ Pass ®Fail ❑Pass ❑ Fail <br /> Is there a sensor in the sump? ® Yes ❑ No ®Yes ❑No ® Yes ❑No ❑Yes ❑ No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA [:]Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? (EYes []No ❑NA ®Yes [—]No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testin ? ®Yes ❑No ❑NA ®Yes [:]No ❑NA ®Yes ❑No [INA ❑Yes [:]No ❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ABOVE IS THE LAST OF TWO BACK TO BACK 15 MINUTE TESTS <br /> 87 MANIFOLD FILL SUMP FAILED-NO VISUAL LEAKS <br /> MAY NEED TO TIGHTEN ELECTRICAL PENETRATIONS <br /> 91 FILL SUMP HAD VISUAL FAIL-WATER LEVEL DROPPED WITHIN 30 MINUTE WAIT TIME-RIPPED ELECTRICAL <br /> PENETRATION <br /> WILL NEED TO REPLACE BOTH ELECTRICAL PENETRATIONS(ONE IS ANGLE) <br />