My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:24 PM
Creation date
6/23/2020 6:54:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1617\PR0231923\UST RETROFIT PLAN 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GETTLER-RYANImc. Appendix V1 ##Job# REC�IVEC <br /> MONITORING SYSTEM CERTIFICATION AUG 14 2015 <br /> For Use By All Jurisdictions Within the State of Cafitomia <br /> Authority Cited:Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 2II <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco 5450 Bldg.No. <br /> Site Address: 1617 W Fremont Street —Cily: Stockton Zip: <br /> Facility Contact Person: Contact Phone No.: <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 7/2812015 <br /> B. Inventory of Equipment Tested/Certified <br /> Check thea boxes to indicate specific!gulpment Insserviced: <br /> Tank ID: TI 87-1 Tank ID: T2 87-2 <br /> 111 In-Tank Gauging Probe. Model: 847390-107 In-Tank Gauging Probe. Model: 846390-107 <br /> M Annular Space or Vault Sensor. Model: 794390-4391 D Annular Space or Vault Sensor. Model: 794390.409 <br /> W Piping Sump i Trench Sensor(s). Model: 794380-208 13 Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> 13 Fill Sump Sensor(s). Model: 794-380-344 13 Fill Sump Sensor(s). Model: 794380-344 <br /> E3 Mechanical Line Leak Detector. Model: 13 Mechanical Line Leak Detector. Model: <br /> 13 Electronic Line Leak Detector Model: 848480 E3 Electronic Line Leak Detector Model: <br /> 111 Tank Overfill/High-Level Sensor. Model: C3 Tank Overfill/High-Level Sensor. Model: Overfill Alarm <br /> 13 Other(speci!y 2quipment type and model in Section E on Page 2). E3 Other(specify equieMent type and model in Section Eon Pa 2, <br /> Tank ID: T3-91 Tank ID: <br /> 12 In-Tank Gauging Probe. Model: 8463 E3 In-Tank Gauging Probe. Model: <br /> M Annular Space or Vault Sensor. Model: 7 94390-409- Io z 0 Annular Space or Vault Sensor. Model: <br /> 13 Piping Sump I Trench Sensor(s). Model: 794380-_208 C3 Piping Sump/Trench Sensor(s). Model: <br /> 13 Fill Sump Sensor(s). Model: 79-4390--344 E3 Fill Sump Sensor(s). Model: <br /> D Mechanical Line Leak Detector. Model: C3 Mechanical Line Leak Detector. Model: <br /> C3 Electronic Line Leak Detector Model: 848480 13 Electronic Line Leak Detector Model: <br /> 11 Tank Overfill/High-Level Sensor. Model: Overfill Alarm E3 Tank Overfill/High-Level Sensor. Model: <br /> C3 Other LsZa equipment type,and model in Section E on Pa 9j 2). ❑ Others equie=t type and model in Section k2iftat&_ <br /> FD—lsp.ser 10: 1-2 Dispenser ID: 3-4 <br /> 13 Dispenser Containment Sensor(s). Model: 794380-208 13 Dispenser Containment Sensor(s). Model: 794380-208 <br /> M Shear Valve(s). ED Shear Valve(s). <br /> E3 Dispenser Containment Floats and Chain(s). E3 Dispenser Containment Floats and Chain(s). <br /> F—D!ispenser 10: 5-6 DispenserID: 7-8 <br /> 13 Dispenser Containment Sensor(s). Model: 794380-208 13 Dispenser Containment Sensor(s). Model: 794380-208 <br /> 13 Shear Valve(s). ED Shear Valve(s). <br /> C3 Dispenser Containment Float(s)and ChainW. 13 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser 10: <br /> 0 Dispenser Containment Sensor(s). Model: 0 Dispenser Containment Sensor(s). Model: <br /> 13 Shear Valve(s). C3 shear Valve(s). <br /> 13 Dispenser Containment Float(s)and Chains 13 Dispenser Containment Float(s)and Chain(! . <br /> -if the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification - I car" that the equipment identified In this document was Inspected/serviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this Inforrnation Is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br /> copy of the report;(check all that apply): 13 System set-up Cip Alarm history revort <br /> Technician Name(print): Joey Mesa Signature: K, <br /> Certification No.: B33787 License,No.: 220793 <br /> Testing Company Name: Gettler-Ryan Inc. Phone No.: 925-561-7555 <br /> Testing Company Address: 6805 Sierra Court Suite G Dublin,CA 94568 Date of Testing/Servicing: 7/28/2015 <br /> Monitoring System Certification Page I of 4 12f07 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.