My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 2:13:24 PM
Creation date
6/23/2020 6:54:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\1617\PR0231923\UST RETROFIT PLAN 2014.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> � . . <br /> ut1C�t:"FE�r®und S>tor1gQ Tc'ZR{C PPOgt'�CiTr�CISp(l3Ction Rdodit <br /> Facility Name: Facility Phone: Date: <br /> ARCO 05450 209 462-1617 JuIv 20 2017 <br /> Facility Address: CERS ID: <br /> 1617 W FREMONT ST STOCKTON CA 95203 10181235 <br /> Inspection Contact: Title: Phone: <br /> Daryl Lee Env. Manager 415 462-1617 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: I Consent Given By: <br /> N Inspection ® Photos ❑ Samples Oz Khan Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Gilbert Garcia 07/06/2019 Ka I nn Rammell 06/15/2018 <br /> Service Technician Manufacturer's Training: <br /> VR 03/12/19;VMI 09/27/18 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> v=violation R=Repeat violation COS=Corrected on site during inspection <br /> 101 HSC 25284 No permit to operate ❑V c R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted c V ❑R ❑COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ❑V ❑R ❑COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan ❑V ❑R ❑COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan ❑V o R c COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V o R ❑COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing c V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ❑V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days c V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually c V ❑R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V ❑R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V o R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days ❑V ❑R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V ❑R ❑COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after c V ❑R ❑COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 119 HSC 25299 Documents were falsified or misrepresented ❑V o R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V o R ❑COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V o R ❑COS <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored o V ❑R o COS <br /> On Site Recoris .. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ❑V o R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V ❑R ❑COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site o V ❑R ❑COS <br /> Pagel of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.