FIED PROGRAM CONSOLIDATED FORM TANK: TA0225701 <br />PR #: PR0232257 <br />UNDERGROUND STORAGE TANKS - TANK PAGE 1 FAC #: FA0000670 <br />(two pages per tank) <br />Page 2 of 7 <br />TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br />(Check only item only) Sr„ '41 v ❑ 7 PERMANENTLY CLOSED ON SITE <br />[j3RENEWAL PERMIT .,ili t E] 8 TANK REMOVED 430 <br />BUSINESS NAME (Same as FACILITY NAME or DBA - Doing Business As) <br />FACILITY ID: <br />PR #: <br />1 <br />QUIK STOP MARKET #148* <br />3 <br />FA0000670 <br />PR0232257 <br />LOCATION WITHIN SITE (optional) 205 W LOCKEFORD ST, LODI 431 <br />PHONE ,`�G �% -_3 p <br />1. TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID# Tank #: 1 432 <br />TANK MANUFACTURER 433 <br />COMPARTMENTALIZED TANK E] Yes No 434 <br />TA0225701 <br />C <br />XERXE S <br />If "Yes", complete one page for each compartment. <br />DATE INSTALLED (YEAR/MO) 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS 437 <br />/ `� �1� .J� <br />10,000 <br />ADDITIONAL DESCRIPTION (For local use only) 438 <br />I1. TANK CONTENTS <br />TANK USE 439 <br />PETROLEUM TYPE 440 <br />® I. MOTOR VEHICLE FUEL <br />® 1 a. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If marked complete Petroleum Type) <br />❑ lb. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br />❑ 2. NON -FUEL PETROLEUM <br />❑ Ic. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑ 99. OTHER <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) qq l <br />CAS# (from Hazardous Materials Inventory page) 442 <br />❑ 4. HAZARDOUS WASTE <br />(Includes Used Oil) <br />/ t �/7 / <br />r U <br />.� lt/9(..T ,(' J C.T�93.(i 4A) <br />�C4 (aC,4 9 <br />❑ 95. UNKNOWN <br />�✓ 8 -7 ���i9iV'i✓ <br />III. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br />(Check one item only) EXTERIOR MEMBRANE LINER ❑ 95. UNKNOWN <br />® 2. DOUBLE WALL ❑ 4. SINGLE WALL M VAULT ❑ 99. OTHER <br />TANK MATERIAL - primary tank ❑ I. BARE STEEL ❑ FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 444 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ® 8. FRP COMPTIBLE W/ 100% METHANOL <br />REINFORCED PLASTIC (FRP) ❑ 99. OTHER <br />TANK MATERIAL - secondary tank ❑ 1. BARE STEEL ❑ 3. FIBERGLASS/ PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 445 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ® 8. FRP COMPTIBLE W/100% METHANOL <br />REINFORCED PLASTIC (FRP) ❑ 10. COATED STEEL ❑ 99. OTHER <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑ 95. UNKNOWN 446 DATE INSTALLED 447 <br />OR COATING <br />❑ 99. OTHER <br />(Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED (For local use only) <br />OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br />PROTECTION IF APPLICABLE PROTECTION <br />❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br />(Check one item only) <br />❑ 2 SACRIFICIAL ANODE (For local use only) <br />SPILL AND OVERFILL YEAR INSTALLE450 TYPE (local use only) 451 <br />OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452 <br />(Check all that appy) N I SPILL CONTAINMENT 1,988,00 <br />❑ 1 ALARM ® 3 FILL TUBE SHUT OFF VAL` 1,993.00 <br />n 2 DROP TUBE 1,988.00 <br />❑ 2 BALL ❑ 4 EXEMPT <br />0 3 STRIKER PLATE 1,988.00 <br />FLOAT <br />IV. TANK LEAK DETECTION (A description of the monitoring program shall be submitted to the local agency.) <br />IF SINGLE WALL TANK (Check all that apply) 453 <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br />❑ I VISUAL (EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING (MTG) <br />(Check one item only) <br />❑ 2 AUTOMATIC TANK GAUGING (ATG) ❑ 6 VADOSE ZONE <br />❑ I VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER <br />® 2 CONTINUOUS INTERSTITIAL MONITORING <br />❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br />❑ 3 MANUAL MONITORING <br />(SIR) BIENNIAL TANK TESTING ❑ 99 OTHER <br />V. TANK CLOSURE INFORMATION / PERMANENT CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455 <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 <br />TANK FILLED WITH INERT MATERIAL? 457 <br />❑ Yes ❑ No <br />UPCF (12/99 revised) <br />