My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_1986-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 1:44:53 PM
Creation date
6/23/2020 6:54:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2003
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232257_205 W LOCKEFORD_1986-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />0 • <br />UNDER DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method By: <br />Test Method Uses: <br />Measuring Equipment Used: <br />Manufacturer • Industry Standard - _ Professional Engr. Other (see below) <br />Pressure Vacuum • Hydrostatic Other (see below) <br />Level Change Indicator (Caldwell System 2001 ! Watton Engineering) <br />Description <br />Disp # 1/2 <br />Disp # 3/4 <br />Was sensor removed for testing? <br />UDC manufacturer <br />Bravo <br />Bravo <br />N/A <br />N/A <br />UDC material <br />Steel <br />Steel <br />T of shut -down resent <br />Float <br />UDC depth (inches) <br />9" <br />9" <br />5' <br />Test start time <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />9:00 AM <br />9:05 AM <br />Height from UDC bottom to lowest <br />Bottom <br />Botype t <br />Change in water level (± 0.000 inches) <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches / i4 Hr.) <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />Condition of UDC prior to testing <br />Comments: <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Was sensor removed for testing? <br />N/A <br />N/A <br />Was sensor property replaced after testing? <br />N/A <br />N/A <br />electrical penetration <br />om <br />T of shut -down resent <br />Float <br />Float <br />Condition of UDC prior to testing <br />Comments: <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Was sensor removed for testing? <br />N/A <br />N/A <br />Was sensor property replaced after testing? <br />N/A <br />N/A <br />Wait time for water level to stabile (hr. -min) <br />0:03 <br />0:05 <br />Depth of water level from UDC bottom (in.) <br />6" <br />5' <br />Test start time <br />8:30 AM <br />8:35 AM <br />Test end tirre <br />9:00 AM <br />9:05 AM <br />Test duration (hrmin) <br />030 <br />0:30 <br />Change in water level (± 0.000 inches) <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches / i4 Hr.) <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />© 2003 Wakon Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.