My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 8:15:16 AM
Creation date
6/23/2020 6:54:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232257_205 W LOCKEFORD_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISP ER CONTAINMENT DC) TESTING <br />Test Method By: O Manufacturer • Industry Standard O Professional Engr¢o Other (see below) <br />Test Method Uses: O Pressure o Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 112 <br />Disp # 314 <br />1:02 PM <br />UDC manufacturer <br />Brovo <br />Brovo <br />Test end time <br />1:17 PM <br />UDC material <br />Steel <br />Steel <br />0.2493 <br />ion of UDC tested <br />Type of shut -down present <br />UDC depth. (inches) <br />9 <br />9 <br />N/A <br />N/A <br />Height from UDC bottom to highest <br />piping penetration <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />TEST RESULT <br />PASS <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Port <br />Depth of water level from UDC bottom (in.) <br />Wait time for water level to stabilize (hr:min) <br />Comments: <br />6 <br />:15 <br />6 <br />:15 <br />Test start time <br />1:02 PM <br />1:02 PM <br />Initial Probe Reading <br />0.2855 <br />0.2495 <br />Test end time <br />1:17 PM <br />1:17 PM <br />Final Probe Reading <br />0.2850 <br />0.2493 <br />ion of UDC tested <br />Type of shut -down present <br />Entire <br />Floats and chains <br />Entire <br />Floats and chains <br />Was sensor removed for testing? <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Wait time for water level to stabilize (hr:min) <br />Comments: <br />6 <br />:15 <br />6 <br />:15 <br />Test start time <br />1:02 PM <br />1:02 PM <br />Initial Probe Reading <br />0.2855 <br />0.2495 <br />Test end time <br />1:17 PM <br />1:17 PM <br />Final Probe Reading <br />0.2850 <br />0.2493 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0005 <br />-0.0002 <br />Pass/Fail threshold (10:002 inches /14 Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />0 2014 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.