Laserfiche WebLink
P11 r a e% P— i % i r— IIS1► <br />MONITCOING SYSTEM CERTIF ATI - <br />MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC JUL .11 2014 <br />CERTIFICATION /TEST DATE: Jul 8, 2014 <br />A1. FACILITY <br />A2. OWNER ENVIRONMENTAL HEALTH <br />Name Quik Stop Market #148 <br />Name Quik Stop Markets, Inc. DEPARTMENT <br />Address 205 W. Lockeford Street, Lodi, CA 95240 <br />Address 4567 Enterprise Street, Fremont, CA 94538 <br />Phone # 510-657-8500 <br />Phone # 510-657-8500 <br />Contact Roger Batra <br />Contact Debbie Markovich <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified June 24, 2014 <br />Lic # 617238 A, B, Haz <br />Inspector Aris Cacapit <br />Contact Dulcinea Covan <br />Phone # 209-468-8257 <br />Phone # 916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check <br />the appropriate boxes to indicate equipment inspected/serviced) <br />B1: <br />TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline - 89 <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />■ Annular Space or Vault Sensor Model: 0794390-409 <br />■ Annular Space or Vault Sensor Model: 0794390-409 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208_ <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />■ Mechanical Line Leak Detector Model: Red Jacket FX <br />■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />Tank #3 (Product): Gasoline - 91 <br />Tank #4 (Product): _ <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />■ Annular Space or Vault Sensor Model: 0794390-409 <br />❑ Annular Space or Vault Sensor Model: <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br />_ <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />62: DISPENSERS/UDC's <br />Dispenser # : 1-2 <br />Dispenser # : 3-4 <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />■ Shear Valves <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # : <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chaln(s) <br />C. CERTIFICATION I certify that the equipment identified In this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this Information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up <br />■ Alarm History Report <br />_ WALTON <br />Signature: ENGINEERING. INC. <br />Technician / Cert #: Curtis Carpenter / B37258 8020679 <br />Date: July 8, 2014 <br />cv ZU14 Walton engineering, mc. <br />