Laserfiche WebLink
• 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.orq/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Facility Inspection <br /> Name: Two Guys Food & Fuel Address: 146 Lathrop Rd. Lathrop, CA Date: Jul 16, 2014 <br /> VIOLATIONS <br /> # C7 C2 M Code Section HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 1 X I 10ther:HSC 25404(e)(4) ISee attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 203. Diesel fuel is weeping from the diesel meter in dispenser#5/6 at a very slow rate and is collecting <br /> on the edge of the diesel filter on 7-16-14 and was not recorded. Any release from the primary <br /> containment that does not escape the secondary containment and was cleaned up within eight hours of <br /> being detected shall be recorded with the following information: <br /> 1. Operator's name and phone number <br /> 2. List of types, quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br /> primary containment <br /> Immediately record this release with the information required, and maintain it on site with the facility's <br /> monitoring records. Submit a copy of the recordable release statement to the EHD by 8-16-14. <br /> 306. Diesel fuel is weeping from the diesel meter in dispenser#5/6 at a very slow rate and is collecting <br /> on the edge of the diesel filter on 7-16-14. All primary containment must be product tight. Immediately <br /> have a properly licensed, trained, and certified contractor replace or repair the failed gasket of the diesel <br /> meter or the leaking component. A permit and inspection by the EHD may be required depending on the <br /> scope of work. If the failed component can't be replaced immediately, there is a possibility that the diesel <br /> UST system may be red tagged to prevent fuel inputs. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Rece' By: Title: <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />