MAINTENANCE HISTORY SOFTWARE REVISION LEVEL <br /> VERSION 329.01 <br /> DISABLED SOFTWARE# 346329-100—B <br /> CREATED — 09.01 .29. 15.44 <br /> TWO GUYS TANK CHART SECURITYS—MODULE# 330160-004—a' <br /> DISABLED SYSTEM FEATURES: <br /> 147 -LATHROP RD PERIODIC IN—TANK TESTS <br /> LATHROP CA 95330 i ANNUAL IN—TANK TESTS <br /> 209-858-2666 CUSTOM ALARMS ISD <br /> DISABLED <br /> JUL 16, 2013 7:52 <br /> SERVICE NOTICE IN—TANK SETUP <br /> DISABLED — — — — — — — — — — — — <br /> SYSTEM STATUS REPORT wN „ <br /> ALL FUNCTIONS NORMAL ISO -3166 COUNTRY T 1 :UNLEADED <br /> PRODUCT CODE 1 <br /> CODE: THERMAL COEFF : .000700 <br /> TANK DIAMETER 96.00 <br /> MASS/DENSITY TANK PROFILE 4 FTS <br /> FULL VOL 10152 <br /> DISABLED 72.0 INCH VOL 8167 <br /> 48.0 INCH VOL : 5076 <br /> 24.0 INCH VOL 1985 <br /> SYSTEM SETUP COMMUNICATIONS SETUP <br /> _ _ — — <br /> FLOAT SIZE: 4.0 IN. <br /> JUL 16, 2013 7:52 WATER WARNING 2.0 <br /> PORT SETTINGS: HIGH WATER LIMIT: 2.5 <br /> COMM BOARD 1 (RS-232) MAX OR LABEL VOL: 10152 <br /> SYSTEM UNITS BAUD RATE 1200 OVERFILL LIMIT 95% <br /> U.S. PARITY : ODD 9644 <br /> SYSTEM LANGUAGE STOP BIT 1 STOP HIGH PRODUCT 93% <br /> ENGLISH DATA LENGTH: 7 DATA 9441 <br /> SYSTEM DATE/TIME FORMAT RS-232 SECURITY DELIVERY LIMIT 15% <br /> MON DD YYYY HH:MM:SS CODE : DISABLED 1522 <br /> TWO GUYS COMM BOARD 3 (EDIM ) LOW PRODUCT 561 <br /> 147 LATHROP RD RS-232 SECURITY LEAK ALARM IMIT: 99 <br /> LATHROP CA 95330 CODE : DISABLED SUDDEN LOS' LIMIT: 99 <br /> 209-858-2666 TANK TILT 0.00 <br /> SHIFT TIMI 1- : DISABLED AUTO TRANSMIT SETTINGS: <br /> PROBE OFFSET 0.00 <br /> SHIFT TIME 2 : DISABLED <br /> SHIFT TIME 3 : DISABLED ,: AUTO LEAK ALARM LIMIT SIPHON MANIFOLDED TANKS <br /> SHIFT TIME 4 '':, DISABLED <. DISABLED T#: NONE <br /> AUTO HIGH WATER LIMIT LINE MANIFOLDED TANKS <br /> TANK PER TST NEEDED WRN DISABLED T#: NONE <br /> DISABLED AUTO OVERFILL LIMIT <br /> TANK ANN TST NEEDED WRN DISABLED <br /> DISABLED AUTO LOW PRODUCT <br /> LEAK MIN PERIODIC: 0!a <br /> LED <br /> LINE RE—ENABLE METHOD AUTOBTHEFT LIMIT 0 <br /> PASS LINE TEST DISABLED LEAK MIN ANNUAL" : 0% <br /> AUTO DELIVERY START 0 <br /> LINE PER TST NEEDED WRN DISABLED <br /> DISABLED AUTO DELIVERY END <br /> LINE ANN TST NEEDED WRN DISABLED PERIODIC TEST TYPE <br /> DISABLED AUTO EXTERNAL INPUT ON <br /> STANDARD <br /> PRINT TC VOLUMES DISABLED <br /> ENABLED AUTO EXTERNAL INPUT OFF ANNUAL TEST FAIL <br /> DISABLED ALARM DISABLED <br /> TEMP COMPENSATION AUTO SENSOR FUEL ALARM PERIODIC TEST FAIL <br /> VALUE (DEG F ) : 60.0 DISABLED <br /> AUTO SENSOR WATER ALARM ALARM DISABLED <br /> STICK HEIGHT OFFSET DISABLED <br /> DISABLED AUTO SENSOR OUT ALARM GROSS TEST FAIL <br /> ULLAGE: 90:d DISABLED ALARM DISABLED <br /> H—PROTOCOL DATA FORMAT ANN TEST AVERAGING: OFF <br /> HEIGHT PER TEST AVERAGING: OFF <br /> DAYLIGHT SAVING TIME <br /> DISABLED TANK TEST NOTIFY: OFF <br /> RE—DIRECT LOCHL PRINTOUT <br /> DISABLED RS-232 END OF MESSAGE <br /> TNK TST SIPHON BREflK:OFF <br /> EURO PROTOCOL PREFIX DISABLED DELIVERY DELAY 3 MIN <br /> S PUMP THRESHOLD 10.00% <br />