My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_1988-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 10:12:50 AM
Creation date
6/23/2020 6:55:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2004
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_1988-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER N ■ IN (UDC) TESTING <br /> >"�>`ef8t11Qd . ..,. :..Mani aeturer r tndt�st Start�tard £ Prafessiona r E Ott a seeb�t <br /> ........................................ <br /> a5t MtFdd` Ses 4 tressure. .:::;::::::;:. . : E3 Vacuum .. ;>: ,H drgstat[c ;: _:::q:L?ther.:. ee:be1.: <br /> .........................:..................................................:........................................................................................................................... <br /> ,.,N.I. surin� qu f patent Used Level..Charge Illat lF ater » eetd n -y ern 2001 r WAIton Engtne� ) <br /> ..: <br /> ....,:: .;.:. CIEs #.: f :.. <br /> UDC Manufacturer Bravo . Bravo <br /> UDC Material Steel ... Steel <br /> UDC Depth(inches) 9" 9" <br /> Height from UDC bottom to highest Bottom Bottom <br /> piping penetration <br /> Height from UDC bottom to lowest Bottom Bottom <br /> 9 <br /> electrical penetration <br /> Condition of UDC prior to testing Dry Dry <br /> Portion of UDC tested Entire Entire <br /> Type of shut-down present Float Float <br /> Was sensor removed for testing? N/A N/A <br /> Was sensor properly replaced after testing? N/A N/A <br /> Wait time for water level to stabilize ) <br /> hr:min 0:15 0:15 <br /> ( <br /> Depth of water level from UDC bottomin. 6" 6" <br /> bottom(in.) <br /> Test start time 2:05 PM 2:06 PM <br /> Test end time 2:35 PM 2:36 PM <br /> Test duration(hr:min) 0:30 0:30 <br /> Change in water levelt 0.000 inches . . <br /> ( ) 0000 0000 <br /> Pass/Fail threshold 0.005 inches/%Hr. 0.005 0.005 <br /> ( ) <br /> TE T RESULT SUL.T <br /> PASS PASS <br /> Comments: <br /> © 2002 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.