My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_1988-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 10:12:50 AM
Creation date
6/23/2020 6:55:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2004
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_1988-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNWI WATER RESOURCES CONTR ((�lz <br /> FORM `B': UND GROUND STORAGE TANK PR R �✓ <br /> TANK PERMIT APPLICATION INFORMATI <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FO EACf'�pl��JtQ.1 1988 0 a <br /> Ip <br /> MARK ONLY EW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION [i`.j 11 , YEf�yIA�NE�.T-Y,C TA <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE pry <br /> ,8;TA��AE141�1NED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID# c14tB. MANUFACTURED BY: <br /> C. YEAR INSTALLED .•ry D. TANK CAPACITY IN GALLONS: CJC� <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. [B'-1—UNLEADED ❑2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OILi 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.i A C.A.S.#: A44 <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF U3"1DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL 3 FIBERGLASS ❑4 STEEL CLADW/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑ 6 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑2 ALKYD LINING 3 EPDXY LINING F-14 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100116 METHANOL? YES ❑ NO ❑ 99 OTHER <br /> ERECT <br /> N ❑ 1 POLYETHLENE WRAP 2 TAR OR ASPHALT ❑ 3 VINYLWRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> ON ❑5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A cu. 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED ACU DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A&14 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br />�- LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> S 6 PRECISION TESTING 7 PRESSURE TESTING P S 91 NONE S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE 41 <br /> 1. ESTIMA�E DATE LAST I4SEIJ(MO/YR) 2. ESTIMATED QUA TITY OF 1 3.WAS TANK FI ED WITH <br /> SUBSTANC R ING IN INERT MAT A ? ❑YES [:] NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PE JURY,AND TO THE BEST OF MY KNOWLEDG ,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> �1 � — <br /> LOCAL AGENCY USE ONLY <br /> C[f�lUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> I I 1 -1 EI I 1 1 131- 1 -31 ,51 ,51 1611-1 0 <br /> CURRENT L AGENCY FACILITY 10# APPROVED BY AAME PHONE S WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PER IT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT CHARGE AMT. FEE CODE IMPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIEDB A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CUR ENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY, ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.