COMPLIANCE INFO_2005-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2005-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 4:16:46 PM
Creation date
6/23/2020 6:55:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2009
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232355_1721 S CHEROKEE_2005-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 6 <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING THE F LLOWING METHOD 490-5 <br /> 490.34b4b <br /> ❑ I.CONTINUOUS ELECTRONIC MONITORING V2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE <br /> _❑4.NO DISPENSERS ❑99.OTHER(Specify): <br /> PANEL MANUFACTURER 490-55 MODEL#: � 490'56 <br /> LEAK SENSOR MANUFACTURER _ 411ITf MODEL#(S): 4W53 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑ a.YES 2 NO 490-59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ ..YES (trb.NO 410-• <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES JK.NO 490.61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER YES ❑b.NO 490.62 <br /> 2.UDC CONSTRUCTION IS 91- ❑2.DOUBLE-WALLED 490.0 <br /> IF DOUBLE WALLED: 490•64a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY:—[]1.LIQUID ❑2.PRESSURE ❑3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a.YES ❑b.NO 490-64b <br /> VII.PERIODIC SYSTEM TESTING <br /> 1. ELD TESTING:THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 49x65. <br /> LEAK DETECTION(BLD)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED CCR§2644.1) <br /> 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490.66 <br /> 3.SPILL BUCKETS ARE TESTED ANNUALLY. `49D-6 <br /> VIII.RECORDKEEPING <br /> The�'ollowing momtoring/mam ance records are kept for this facility: <br /> IKAlarm logs 4"0. ffllVisual Inspection Records 490•69b ❑Tank integrity testing results 4 680 <br /> ❑SIR testing results(and supporting documentation records). 490-6sa ❑ Tank gauging results(and supporting documentation records). 490-69. <br /> ❑ATG Testing results(and supporting documentation records).490-6sr ❑ Corrosion Protection 60-day logs 49uss <br /> eEquiprtment maintenance and calibration records. 490.68h <br /> IX.TRAINING <br /> ersonnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 49o-6% <br /> REFS NCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> IS UNDERGROUND STORAGE TANK MONITORING PLAN(Requited)490.69b <br /> ff'OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)49o-6% <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-693 <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW 49o.69e <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION'49o•69r <br /> ❑ WRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-69s <br /> OTHER(Specify):m69h,m6% -Written Procedures&Best Management Practices for Monitoring Double Containment UST Systems" <br /> This facility has a"Designated UST Operator'who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> Names of contact person(s)for emergencies and monitoring alarms.49o.7o <br /> X :COMMENTS/ADDITIONAU FORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.4W71 <br /> OVERFILL PREVENTION(OR PROTECTION)IS ACCOMPLISHED BY THE FOLLOWING TWO(2)METHODS: <br /> 1. MECHANICAL OVERFILL VALVES INSTALLED 1N DROP TUBES,SET TO TRIP AT 95%FULL LEVEL. <br /> 2. SERVICE PENETRATIONS TO THE PRIMARY CONTAINMENT ARE CONTAINED WITHIN SUMPS,INCLUDING FILL&VAPOR RETURN. <br /> XL PERSONNEL RESPONSIBILITIES' <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all nwnitoring records are maintained properly. <br /> The following person(s)aro responsible for performing the monitoring and equipment maintenance: <br /> NAME HARBHAJAN&DEVINDER SHERGILL 490-72 TITLE FRANCHISEES 490-73 <br /> NAME SAMI ALKOUSSA 490-74 TITLE DISTRICT ADVISOR 490.75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII.OWNERIOPERATOR`SIGNA <br /> CERTIFICATION:I certify that the inform on provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATURE ` 49076 DATE: 490M <br /> SEPTEMBER 15,2008 <br /> or.! 0 A R f <br /> APPLICANT NAME(print): 4W78 APPLICANT TITLE: 490-79 <br /> MIKE KARVELOT DIRECTOR OF ENVIRONMENTAL AFFAIRS <br /> UPCF UST-D(12/2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.