My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2512
>
2300 - Underground Storage Tank Program
>
PR0232418
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:16:02 PM
Creation date
6/23/2020 6:55:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0232418
PE
2361
FACILITY_ID
FA0004064
FACILITY_NAME
WATERLOO LIQUOR
STREET_NUMBER
2512
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
14128102
CURRENT_STATUS
01
SITE_LOCATION
2512 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232418_2512 E WATERLOO_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
429
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.oW hd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WATERLOO LIQUOR 12512 E WATERLOO RD, STOCKTON April 04, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS),CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days. <br /> A new designated operator was hired in May 2016 and notification was not provided to the EHD within 30 days of <br /> the change. Any changes shall be reported to the EHD within 30 days. Immediately log into the California <br /> Environmental Reporting System (CERS)at http://cers.calepa.ca.gov and upload the notification identifying all the <br /> designated operators for this facility. <br /> This is a minor violation. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The maintenance records alarm <br /> logs or records of follow up actions for"SN2 sensor on alarm" on 04/29/2016 were not found on site. These records <br /> shall be maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or <br /> sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br /> equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations. <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies to the EHD. <br /> This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the May 25, 2016 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: "SN2 sensor on alarm"for Dispenser3/4, Dispenser 1/2, Diesel Annular, UNL Annular, <br /> Diesel Sump, and Prem Sump that occurred on 04/29/206. During the monthly inspection, the designated operator <br /> shall review the alarm history for the previous month, check that each alarm was documented and responded to <br /> appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the <br /> monthly report. Ensure that designated operators performing monthly inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a minor violation. <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> The audible alarm on the control panel failed to activate when tested to ensure continuous monitoring of the tank <br /> system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br /> product at the dispenser when it detects a leak. Correct immediately by having a properly licensed, trained, and <br /> certified contractor replace the failed component with a functional component(LG 113-x listed, if applicable) and <br /> obtain a permit within one business day from the EHD. If the failed component can't be replaced immediately, there <br /> is a possibility that the UST system may be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> FA0004064 PR0232418 SCO01 04/04/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.