My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_1990-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 1:17:18 PM
Creation date
6/23/2020 6:55:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2003
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_1990-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MonitorhoSystem Equipment 41 ertifictio <br />For Use By All Jurisdictions Within The State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br />to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br />within 30 days of test date. <br />A. General Information <br />Facility Name: Shell 136187 <br />Site Address: 2375 W. Grant Line (� 1-205 <br />Facility Contact Person: Shauna <br />Bldg. No.: <br />City: Tracy, CA Zip: 95376 <br />Contact Phone No.: (209) 836-8908 <br />Make/Model of Monitoring System: V/R Simplicity Date of Testing/Servicing: 05/08/02 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: 01 - Regu <br />Tank ID• 02 -Plus <br />K In - Tank Gauging Probe. <br />Model: <br />VR 847399.107 <br />IN hi - Tank Gauging Probe. Model:VR 847390.107 <br />N Annular Space or Vault Sensor. <br />Model: <br />VR 794380-301 <br />N Annular Space or Vault Sensor. <br />Model: <br />VR 794380.301 <br />N Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380.352 <br />0 Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380.352 <br />❑ Fill Sump Sensor (s). <br />Model: <br />None <br />❑ Fill Sump Sensor (s). <br />Model: <br />None <br />❑ Mechanical Line Leak Detector. <br />Model: <br />None <br />❑Mechanical Line Leak Detector. <br />Model: <br />None <br />RD Electronic Line Leak Detector. <br />Model: <br />VR 331198.001 <br />Ig Electronic Line Leak Detector. <br />Model: <br />VR 331198-001 <br />❑ Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />❑ Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />29 Other ( specify equipment type and model in Section E on Page 2). <br />19 Other ( specify equipment type and model in Section E on Page 2). <br />Tank ID• 03 - Prem <br />Tank ID• 04 -Diesel <br />IM In - Tank Gauging Probe. <br />Model: <br />VR 847390.107 <br />K In - Tank Gauging Probe. <br />Model: <br />VR 847390-107 <br />Annular Space or Vault Sensor. <br />Model: <br />VR 794380.301 <br />Ig Annular Space or Vault Sensor. <br />Model: <br />VR 794380-301 <br />Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380.352 <br />09 Piping Sump \ Trench Sensor (s). <br />Model: <br />VR 794380-352 <br />❑ Fill Sump Sensor (s). <br />Model: <br />None <br />❑ Fill Sump Sensor (s). <br />Model: <br />None <br />❑ Mechanical Line Leak Detector. <br />Model: <br />None <br />❑Mechanical Line Leak Detector. <br />Model: <br />None <br />® Electronic Line Leak Detector. <br />Model: <br />VR 331198.001 <br />Electronic Line Leak Detector. <br />Model: <br />VR 849490.003 <br />❑ Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />❑ Tank Overfill \ High -Level Sensor. <br />Model: <br />None <br />99 Other ( specify equipment type and model in Section E on Page 2). <br />❑ Other ( specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 01-02 <br />I <br />Dispenser ID: 03-04 <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />None <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />None <br />I8 Shear Valve (s). <br />09 Shear Valve (s). <br />lil Dispenser Containment Float (s) and Chain (s). <br />Ig Dispenser Containment Float (s) and Chain (s). <br />Dispenser ID• 05-06 <br />r ID: 07-08 <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />None <br />Containment Sensor (s). <br />Model: <br />None <br />99 Shear Valve (s). <br />EDispenser <br />alve (s). <br />lig Dispenser Containment Float (s) and Chain (s). <br />er Containment Float (s) and Chain (s). <br />Dispenser ID: 09-10 <br />Dispenser ID: 11-12 <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />None <br />❑ Dispenser Containment Sensor (s). <br />Model: <br />None <br />19 Shear Valve (s). <br />99 Shear Valve (s). <br />09 Dispenser Containment Float (s) and Chain (s). <br />Rg Dispenser Containment Float (s) and Chain (s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturer's guidelines. Attached to this Certification is information (e.g. manufactures' checklists ) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the; ( check all that apply): ❑ System set-up ❑ Alarm history report <br />Technician Name (print): SSS4osh Signature: Original on file at SSS <br />Certification No.: 552-61-6176 <br />License. No.: 485184 <br />Testing Company Name: Ser. Sta. Sys. Phone No.: (408) 971-2445 <br />Site Address: 2375 W. Grant Line @ 1-205 Date of Testing/Servicing: 05/08/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.