My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_1990-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 1:17:18 PM
Creation date
6/23/2020 6:55:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2003
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_1990-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S <br />0 <br />• f'iiili,•„ <br />State and local laws regulations require that equipment which monitors tanks and/or piping systems containing hazardous <br />materials be tested/serviced annually or on a schedule specified by the manufacturer, whichever is more frequent. This form, or a <br />service report with equivalent information, must be used to document testing and servicing of monitoring equipment. If more <br />than one monitoring system (e.g. Veeder-Root TLS -350, Ronan X76S, etc.) is installed at the facility, a separate certification or <br />report must be prepared for each monitoring system by the technician who performs the work. <br />Date of Testing/Servicing: 6-5-00 <br />Site Address: 2375 Grantline Rd. <br />Facility Name: Shell <br />City: Tracy Zip: 95376 <br />Facility Contact Person: Bill Contact Phone No.: (209) 836-8908 <br />Make/Model of Monitoring System: Veeder Root/Simplicity Location of Control Panel: Back Room <br />Make/Model of Line Leak Detector (LLD): Veeder Root/PLLD LLD Leak Threshold: 3.0 g.p.h_ <br />rmmnlntP the fnllnwinu checklist: <br />X <br />Yes <br />Tank ID No.: Premium <br />No* <br />Monitoring system is operable per manufacturer's specifications? <br />X <br />Yes <br />Annular Space Sensor <br />No* <br />Audible alarm iso erational? <br />X <br />Yes <br />Piping Sump Sensor <br />No* <br />Visual alarm isoperational? <br />X <br />Yes <br />X <br />No* <br />Monitoring system is secured from unauthorized tampering? <br />X <br />In -Tank Gauging Probe <br />No* <br />For pressurized piping systems, do the turbines automatically shut down if the monitoring system detects a leak, fails <br />Dispenser Containment Sensor(s) <br />Dispenser Containment Sensor(s) <br />Mechanical Line Leak Detector <br />to operate, or is electrically disconnected? If yes, which monitoring devices initiate positive shut down? <br />Mechanical Line Leak Detector <br />Mechanical Line Leak Detector <br />N/A <br />Electronic Line Leak Detector <br />X <br />LYe <br />X Electronic Line Leak Detector <br />X <br />PLLD/Sump Sensor <br />Fill Sump Sensor <br />Fill Sump Sensor <br />No* <br />For monitoring systems which serve as tank overfill warning devices, does the overfill warning function operate <br />Fill Sump Sensor <br />TLM Sump Sensor <br />TLM Sump Sensor <br />properly? If so, at what percent of tank capacity does the alarm trigger? 90% <br />TLM Sump Sensor <br />N/A <br />*In the comments section below, describe how and when these deficiencies will be corrected. <br />Check the a ro riate boxes to indicates ecific equipment ins ectad/serviced: <br />Tank ID No.: Regular <br />Tank ID No.: Plus <br />Tank ID No.: Premium <br />Tank ID No.: Diesel <br />Annular Space Sensor <br />X1 <br />Annular Space Sensor <br />Annular Space Sensor <br />X <br />Annular Space Sensor <br />Piping Sump Sensor <br />X <br />Piping Sump Sensor <br />Piping Sump Sensor <br />X <br />Piping Sump Sensor <br />In -Tank Gauging Probe <br />X <br />In -Tank Gauging Probe <br />X In -Tank Gauging Probe <br />X <br />In -Tank Gauging Probe <br />Dispenser Containment Sensor(s) <br />Dispenser Containment Sensor(s) <br />Dispenser Containment Sensor(s) <br />Dispenser Containment Sensor(s) <br />Mechanical Line Leak Detector <br />Mechanical Line Leak Detector <br />Mechanical Line Leak Detector <br />Mechanical Line Leak Detector <br />Electronic Line Leak Detector <br />X <br />Electronic Line Leak Detector <br />X Electronic Line Leak Detector <br />X <br />Electronic Line Leak Detector <br />Fill Sump Sensor <br />Fill Sump Sensor <br />Fill Sump Sensor <br />Fill Sump Sensor <br />TLM Sump Sensor <br />TLM Sump Sensor <br />I TLM Sump Sensor <br />TLM Sump Sensor <br />Are impact valves operational per manufacturer's specifications? I X I YES I I NO 11 <br />Comments: Dispenser pans have Float and Chain style sensors. <br />I certify that the equipment identified above was inspected/serviced in accordance with manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturer's checklist, etc.) necessary to verify that the above <br />information is correct and to describe any repairs, replacement, or recalibration of equipment. <br />Name of Qualified Technician (print): <br />Ron Wood <br />Signature: Signature on file at SSS <br />Testing Company Name: Service Station Systems, Inc. Phone No.: (408) 971-2445 <br />
The URL can be used to link to this page
Your browser does not support the video tag.