Laserfiche WebLink
9 <br />TEST DATE: 05/05/98 <br />CLIENT: SHELL OIL COMPANY <br />Tank ID: <br />Product: PREMIUM <br />Capacity in gallons: 11,587 <br />Diameter in inches: 90.00 <br />Length in inches: 426 <br />Tank age (years): <br />Fuel pure rating: <br />CP installed on: <br />1 Material: DW FIBERG <br />Tank manifolded: NO <br />Vent manifolded: NO <br />Vapor recovery manifolded: YES <br />Impact Valves Operational: y <br />Overfill protection: YES <br />Overspill protection: YES <br />WORK ORDER NUMBER: 2204563 <br />SITE: SHELL 204-7884-1305 <br />Bottom to top fill in inches: <br />Bottom to grade fill in inches: <br />Fill pipe length in inches: <br />Fill pipe diameter in inches: 4.0 <br />Stage I vapor recovery: DUAL <br />Stage II vapor recovery: ASSIST <br />Installed: ATG <br />COMMENTS <br />LINE A (EAST) SUPPLIES DISP# 15-22, LINE B (WEST) SUPPLIES DISP# 1-6, 11-14. <br />Dipped Water Level: <br />Dipped Product Level: <br />Probe Water Level: <br />Ingress Detected: Water Bubble <br />Test time: <br />VacuTect Test Type: <br />VacuTect Probe Entry Point: <br />Pressure Set Point: <br />Tank water level in inches: <br />Water table depth in inches: <br />Determined by (method): <br />Result: <br />COMMENTS <br />w/passed Failed/replaced New/passed <br />L.D. #1 L.D. #1 L.D. #2 <br />Make: RED JACKET <br />Model: X.L.P. <br />Ullage SIN: 401926731 <br />Open time in sec: 1.00 <br />Holding psi: 12 <br />Resiliancy cc: 300 <br />Test leak rate ml/m: 189.0 <br />Metering psi: 10 <br />Calib. leak in gph: 3.00 <br />Results: PASS <br />COMMENTS <br />Material: <br />DW FIBERG <br />DW FIBERG <br />Diameter (in): <br />2.0 <br />2.0 <br />Length (ft): <br />150.0 <br />150.0 <br />Test psi: <br />50 <br />50 <br />Bleedback cc: <br />240 <br />250 <br />Test time (min): <br />30 <br />30 <br />Test 1: Start time: <br />11:20 <br />12:40 <br />Finish psi: <br />49 <br />so <br />Vol change cc: <br />4 <br />0 <br />Test 2: Start time: <br />11:31 <br />12:51 <br />Finish psi: <br />50 <br />50 <br />Vol change cc: <br />0 <br />0 <br />Test 3: Start time: <br />11:42 <br />13:02 <br />Finish psi: <br />50 <br />50 <br />Vol change cc: <br />0 <br />0 <br />Final gph: <br />0.002 <br />0.000 <br />Result: <br />PASS <br />PASS <br />Pump type: <br />PRESSURE <br />PRESSURE <br />COMMENTS Pump make: <br />RED JACKET <br />RED JACKET <br />RED JACKET <br />X.L.D. <br />111930674 <br />1.00 <br />10 <br />115 <br />189.0 <br />10 <br />9.00 <br />PASS <br />L.D. #2 <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 Printed 05/12/98 14:12 MSHAW I <br />