My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL-04-2011 09:51 Service Station Systems 408 938 8888 P.05 <br /> Monitoring System Certification-Page 3 of 3 <br /> Site Address: 2375 W.Grant Line Date of Testing/Servicing: 6/10111 <br /> F. In -Tank Gauging/SIR Equipment; 0 Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perforin leak detection monitoring. <br /> Com lets the following checklist; <br /> 0 Yes p No* Has all input wiring;been inspected for proper entry and termination,including testing for ground faults? <br /> 13 Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup'? <br /> ❑ Yes ❑ No* Was accuracy of system product level readings tested? <br /> ❑ Yes ❑ No* Was accuracy of system water level readings tested? <br /> ® Yes ❑ No* Were all probes reinstalled properly? <br /> ® Ycs ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> * In Section H below,describe how and when these deficiencies were or will be corrected. <br /> G. line Leak Detectors(LLD): ❑ Check this box if LLD's are not installed. <br /> Com lets the following checklist: <br /> 0 Yes ❑ No* .For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? <br /> ❑ N/A (Check all that apply) Simulated leak rate: 0 3 g.p.h.(1.); 0 0.l g.p.h.(2.); ❑ 0.2 g.p.h.(2.). <br /> Notes: 1. Required for equipment start-up certification armed annual certification. <br /> 2. Unless mandated t local Sency,certification required only for electronic LLD start-up. <br /> 8 Yes 0 No* Were all LLD's confirmed o erational and accurate within regulatory requirements? <br /> M Yes ❑ No* Was the testing a aratus Eroeerl calibrated? <br /> D Yes C No* For mechanical LLD's,does the LLD restrict product flow if it detects a leak? <br /> a N/A <br /> M Yes ❑ No* For electronic I.I,D's,does the turbine automatically shut off if the LLD detects a leak? <br /> ❑ N/A <br /> 8 Yes R No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> r9 MIA nr Mannnnanto-A9 <br /> 2 Yes D No* For electronic LLD's,does the turbine automatically shut off if any portion of the monitoring system <br /> ❑ N/A malfunctions or fails a test? <br /> ® Yes 0 No* For electronic LLD's,have all accessible wiring connections been visually inspected? <br /> ❑ N/A <br /> a Yes I O No* I Were all items on the equipment manufacturer's maintenance checklist completed? <br /> * in Section H below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br />