2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 2:40:22 PM
Creation date
6/23/2020 6:56:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\2375\PR0232469\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUN-20-2011 07:45 Service Station Systems 408 938 8888 P.12 <br /> 12. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With rill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested Q <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard i7 Professional Engineer <br /> ®Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum M Hydrostatic <br /> ®Other(Spec) <br /> Test Equipment Used: [neon Sump Tester Equipment Resolution: +/-0.002" <br /> Fill Sume#87 Fill-SUME#89 Fill Sump#91 Fill Sump#Diesel <br /> Sum Diameter: 42" 42" 42" 42" <br /> Sum Depth: 82" 82" 82" 82" <br /> Height from Tank Top to Top of N/A N/A N/A N/A <br /> Hi est Piping Penetration. <br /> Height from Tank Top to Lowest 24" 24" 24" 24" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good Good Good <br /> testing: <br /> Portion of Sump Tested 2"above i in 2"above piping 2"above piping 2"above piping <br /> Sump Material: FibeEglass Fiber Iass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 8:11 am 8:11 am 8:11 am 8:11 am <br /> Initial Readin W: 3.8838 3.3982 3.7636 1.0956 <br /> Test End Time: 8:26 am 8:26 an 8:26 am 8:26 am <br /> Final Readin RF): 3.8844 3.4000 3.7633 1.0967 <br /> Test Duration: 15 min. 15 min. 15 min. 15 min. <br /> Change in Reading(Rr-Rt : +0.0006 +0.0018 -0.0003 +0.0011 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: M Pass 0 Fail M Pass ❑Fail ® pass D Fail ® Pass 0 Fail <br /> is there a sensor in the sump? a Yes ❑No ® Yes ❑No ® Yes ❑No ® Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is p Yes D No ®NA ❑Yes El No ®NA D Yes❑No ®NA ❑Yes❑No ®NA <br /> detected? <br /> Was sensor removed for testing? ®Yes❑No ❑NA ®Yes❑No ❑NA 14 Yes❑No ❑NA ®Yes p No ❑NA <br /> Was sensor properly replaced and ®Yes❑No 0 NA C!lyes Q No ONA ®Yes❑No ❑NA ®Yes❑No ❑NA <br /> verified functional after testing? <br /> Comments-(include information o"repairs made prior to testing, and recommended follow-up for aided tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> TOTAL P.12 <br />