My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 4:12:21 PM
Creation date
6/23/2020 6:56:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />El <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: <br />❑ UDC Manufacturer N Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />N Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon Sump Tester <br />Equipment Resolution: +/- 0.002" <br />UDC # 17/18 <br />UDC # 19/20 <br />UDC # 21/22 <br />UDC Manufacturer: <br />OPW <br />OPW <br />OPW <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />31" <br />31" <br />3111 <br />Height from UDC Bottom to Top <br />21" <br />22" <br />21" <br />of Hi est Piping Penetration: Ii <br />Height from UDC Bottom to <br />6" <br />6" <br />6" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Good <br />Good <br />Good <br />testing: <br />Portion of UDC Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />product and water)?' <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />❑ yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />safe shutdown? <br />Was fail-safe verified to be <br />❑ yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />❑ Yes ❑ No N NA <br />op erational? <br />Wait time between applying <br />pressure/vacuum/water and <br />30 minutes <br />30 minutes <br />30 minutes <br />starting test <br />Test Start Time: <br />Initial Reading (RI): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF -RI): <br />Pass/Fail Threshold or Criteria: <br />+/-0.002" <br />+/-0.002" <br />+/- 0.002" <br />Test Result: <br />❑ Pass rx-1 Fail <br />❑ Pass -IM Fail <br />❑ Pass © Fail <br />Was sensor removed for testing? <br />N Yes ❑ No ❑ NA <br />N Yes ❑ No ❑ NA <br />N Yes ❑ No ❑ NA <br />Was sensor properly replaced Lnlverified <br />®yes ❑ No ❑ NA <br />®Yes ❑ No E3NA <br />N Yes EJNo ❑ NA <br />functional after testin <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />i°Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />17/18, 19/20, & 21/22 — Failed due to torn penetration conduits. R -r s T f t <br />A c 4 <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page