My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 4:12:21 PM
Creation date
6/23/2020 6:56:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AW 0 0 G" <br /> San Joaquin County FILE �� <br /> 1•�it'�A <br /> Environmental Health Department <br /> w :< <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Compliance Review Report <br /> Facility Name: Facility Phone: Date: <br /> GRANT LINE SHELL' (209)836-8908 April 24, 2018 <br /> Facility Address: CERS ID: <br /> 2375 W GRANT LINE RD,TRACY, CA 95376 10181399 <br /> Inspection Contact: Title: Phone: <br /> lz Mr,.sem � I `,, <br /> The following non-inspection related violations listed below from the California Health and Safety Code(HSC), California <br /> Code of Regulations(CCR)and/or the Code of Federal Regulations(CFR)were found. <br /> #10,,� C,'2s �F�II o o �a�.;. .�e apes:_ fro EH�1 tldng"��.ttot ltmtted fi. it�patd;fs � #� <br /> OBSERVATIONS:Due to a failed routine secondary containment testing,violations have been issued and a 2018 permit <br /> to operate the UST system has not been issued. No person may own or operate an UST unless a permit for its operation <br /> has been issued by the local agency to the owner or operator of the UST system. Immediately obtain a permit to operate a <br /> UST system from the EHD.An"Operating without a Permit'penalty applies. <br /> This is a Class I violation. <br /> FGotll11Ett � <br /> . . _ <br /> OBSERVATIONS:Secondary containment testing was last performed on April 15,2014 and was due by April 2017 and <br /> the tank annulars were not tested. Testing has not been completed and is 12 months past due. Secondary containment <br /> testing is required once every 36 months. Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a Class II violation. <br /> OBSERVATIONS:An inspection was last done on March 21, 2017 and an inspection report was issued identifying <br /> information to be submitted to bring this site into compliance. This information was required to be submitted within 30 days <br /> of receiving the inspection report. This information has not been received resulting in a non-compliant status for this <br /> facility. An operator that receives an inspection report shall have 30 days to submit a written response that includes a <br /> statement documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class II. <br /> HS G290 �29tb.2 � ? � 1atnlmlro sdalltatn notl�� ` <br /> OBSERVATIONS:The April 12, 2017 secondary containment test results indicate a failure at the diesel secondary <br /> product,87 secondary product, 89 secondary product, 91 secondary product, all turbine sumps, and UDCs 1/2, 3/4, 9/10, <br /> 11/12, 15/16, 17/18, 19/20, 21/22. All secondary containment for the UST system must be tight. To date, no repairs have <br /> been made. Immediately have a properly licensed,trained, and certified contractor repair or replace the failed component <br /> unA�permiand inspection of the EHD. <br /> / Is Is a minor violation. <br /> FA0003772 PR0232469 SCO21 04/24/2018 <br /> Rev.01/08/16 Page 1 of 2 Underground Storage Tank Program Compliance Review Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.