My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2021 4:12:21 PM
Creation date
6/23/2020 6:56:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232469_2375 W GRANT LINE_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
p,(1UI/y • <br /> SA NUJ 0 U l N Environmental Health Department <br /> COUNTY Linda Turkatte, REHS, Director <br /> Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu, REHS <br /> November 30, 2017 <br /> Scott Willett <br /> DiMaggio Maintenance, Inc. <br /> 2603 Industry Avenue. <br /> Oceanside, CA 92054 <br /> Re: Shell SR0078055 <br /> 2375 W. Grant Line Rd., Tracy, CA 95377 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br /> application for a permit to cut concrete next to all eleven UDCs, remove and replace all piping <br /> penetration fittings in the UDCs, replace a damaged section of 89 piping, remove and replace piping <br /> penetration fittings in all four STP sumps on the underground storage tank (UST) system at the above <br /> noted address. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Stacy Rivera at (209) 468-3440 to arrange the following inspection appointments (a <br /> 48-hour notice is required for inspection appointments). Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval. <br /> a. Primary piping soap test: One hour pneumatic pressure test at 110% of operating pressure, <br /> or 40 psi, whichever is greater. <br /> b. Secondary piping soap test: One hour pressure test per manufacturer's guidelines. If there <br /> are no manufacturer's guidelines, test shall be performed using an applicable method <br /> specified in an industry code or engineering standard. <br /> c. 24-hour hydrostatic test (or equivalent) on all eleven UDC sumps and all four STP sumps <br /> (87, 89, 91, diesel). <br /> d. Secondary containment testing on all four product pipes (87, 89, 91, diesel) after backfill. <br /> e. If concrete will be broken over the tanks, a secondary containment test must be performed <br /> on the affected tank(s) once concrete is poured in accordance with the manufacturer's <br /> guidelines. <br /> f. If 89 primary piping is replaced, soil sampling under the replaced piping must be witnessed <br /> by EHD. A signed Authorization to Release form will be required. <br /> Please be aware that the facility cannot operate the UST system prior to the EHD <br /> inspection and approval. <br /> 4. Secondary containment testing for the UDCs, STP sumps, and piping is required six months <br /> after installation. Provide 48 hours notification to the EHD when this test is scheduled. <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page