My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
121
>
2300 - Underground Storage Tank Program
>
PR0232594
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 3:25:01 PM
Creation date
6/23/2020 6:56:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0232594
PE
2361
FACILITY_ID
FA0004573
FACILITY_NAME
SJ COUNTY PARKING GARAGE
STREET_NUMBER
121
Direction
S
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
14912001
CURRENT_STATUS
01
SITE_LOCATION
121 S SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232594_121 S SAN JOAQUIN_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+. SAN.►JOAQUIN <br />tom, k k --COU N T Y -- <br />e, <br />• <br />Environmental Health Department <br />} tJndergrou'nd Storage Tank Pragram tnspl`ection Report <br />r, <br />Facility Name: Facility Phone: <br />SJ COUNTY PARKING GARAGE (209) 468-3099 <br />Date: <br />July 25, 2018 <br />Facility Address: <br />121 S SAN JOAQUIN ST, STOCKTON, CA 95202 <br />CERS ID: <br />10181667 <br />Inspection Contact: <br />David Meyers <br />Title: <br />Environmental <br />Phone: <br />(209) 468-9745 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />12361 - UST FACILITY <br />Consent For: <br />❑x Inspection ❑O Photos ❑ Samples <br />Consent Given By: <br />Toby Baptiste, Manager <br />Service Technician Onsite: <br />Zane Nimmo <br />Exp. Date: <br />06/02/2019 <br />Designated Operator: <br />Nicholas Graham -Lewin <br />Exp. Date: <br />04/18/2020 <br />Service Technician Manufacturer's Training: <br />VR, 07/25/18; VMI, 01/08/18 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V =Violation R = Repeat violation COS = Corrected on site during inspection <br />Fite Review <br />101 <br />HSC 25284 <br />Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees <br />o V <br />o R o COS <br />102 <br />HSC 25284(a)(3)(A)/(B) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />o V <br />o R o COS <br />103 <br />HSC 25292.2, 25299.30 <br />Current financial responsibility documents not submitted <br />o V <br />o R ❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />o V <br />❑ R o COS <br />105 <br />CCR 2632(d)(1), <br />2634(d) <br />Failed to have an approved UST monitoring plan <br />o V <br />o R o COS <br />106 <br />CCR 2632(d)(2), <br />2634(e) <br />Failed to have an approved UST response plan <br />o V <br />❑ R o COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V <br />■ R c COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V <br />o R o COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />o V <br />o R o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />o V <br />c R ❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V <br />o R o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />o V <br />❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />o V <br />o R c COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />o V <br />o R o COS <br />115 <br />CCR 2715(a) <br />Failed to submit to EHD notification of designated operator identification or change w/in 30 days <br />o V <br />❑ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />o R o COS <br />117 <br />CCR 2663(h) <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />o V <br />o R o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />o V <br />o R o COS <br />119 <br />HSC 25299(a)(8), <br />25299(b)(7) <br />Documents were falsified or misrepresented <br />o V <br />o R o COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />o V <br />o R ❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />o V <br />❑ R o COS <br />122 <br />CCR 26310) <br />Failure to submit and maintain UST system component statement of compatibility for substance stored <br />o V <br />o R o COS <br />Site Reoords <br />201 CCR 2712(b) <br />Failure to maintain monitoring, maintenance, and follow up action records <br />❑ V <br />o R o COS <br />FA0004573 PR0232594 SCO01 07/25/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 1 of 4 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.