My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
2771
>
2300 - Underground Storage Tank Program
>
PR0234251
>
COMPLIANCE INFO_1989-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2021 12:53:25 PM
Creation date
6/23/2020 6:56:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2010
RECORD_ID
PR0234251
PE
2361
FACILITY_ID
FA0003508
FACILITY_NAME
TULARE FARMS LLLP
STREET_NUMBER
2771
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
17710025
CURRENT_STATUS
01
SITE_LOCATION
2771 E FRENCH CAMP RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0234251_2771 E FRENCH CAMP_1989-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NIFIED PROGRAM CONSOLIDATED FOi� TANK: TA0425104 <br />/ PR #: PR0234251 <br />FAC #: FA0003508 <br />UNDERGROUND STORAGE TANKS -TANK G ((( <br />qq <br />k yj <br />VI. PIPING CONSTRUCTION (Check all that apply) Page'5 of 5 <br />UNDERGROUND PIPING <br />ABOVEGROUND PIPING <br />SYSTEM TYPE ❑ 1. PRESSURE 912. SUCTION ❑ 3. GRAVITY 458 <br />❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 459 <br />CONSTRUCTION ❑ 1. SINGLE WALL ❑3. LINED TRENCH ❑ 99. OTHER 460 <br />❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462 <br />❑X 2. DOUBLE WALL E195.UNKNOWN <br />❑ 2. DOUBLE WALL ❑ 99. OTHER <br />MANUFACTURER AMERON/GALVANIZED 461 <br />MANUFACTURER 463 <br />❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE w/ 100%METHANOL <br />❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE w/ 100%METHANOL <br />❑ 2. STAINLESS STEEL ® 7. GALVANIZED STEEL <br />❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ PLASTIC COMPATIBLE W/ CONTENTS ❑ 95. UNKNOWN <br />❑ PLASTIC COMPATIBLE W/ CONTENTS ❑ 95. UNKNOWN <br />® 4. FIBERGLASS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 4. FIBERGLASS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 464 <br />❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION 465 <br />VII. PIPING LEAK DETECTION (Cheek all that apply) (A description of the monitoring program shall be submitted to the local agency.) <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SINGLE WALL PIPING 466 <br />SINGLE WALL PIPING 467 <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br />FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION+ AUDIBLE AND <br />FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION+ AUDIBLE AND <br />VISUAL ALARMS. <br />VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 2. MONTHLY 0.2 GPH TEST ❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 3. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 4. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS <br />CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />❑ S. DAILY VISUAL MONITORING OF PUMPING SYSTEM + TRIENNIEAL PIPING <br />❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />INTEGRITY TEST (0.1 GPH) <br />❑ 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): <br />7. SELF MONITORING <br />F-17. SELF MONITORING <br />RAVITY FLOW <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1) GPH <br />GRAVITY FLOW (Check all that apply): <br />❑ 8. DAILY VISUAL MONITORING <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1) GPH <br />SECONDARILY CONTAINED PIPING <br />SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (Check all that apply): <br />PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) <br />ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />❑ b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />❑ b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION <br />DISCONNECTION <br />❑ c. NO AUTO PUMP SHUT OFF <br />❑ c. NO AUTO PUMP SHUT OFF <br />❑ 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUT OFF OR <br />❑ 11. AUTOMATIC LEAK DETECTOR <br />RESTRICTION <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM <br />SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF * <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br />AUDIBLE AND VISUAL ALARMS <br />AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />SHUT OFF OR RESTRICTION <br />SHUT OFF OR RESTRICTION <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK <br />❑ 17. DAILY VISUAL CHECK <br />VIII. DISPENSER CONTAINMENT <br />DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br />DATE INSTALLED46S 111, CONTINUOUS DISPENSER PAN SENSOR + AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER / MONITORING <br />Zn�`--� *�$43. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ® 6. NONE <br />ISPENSER+AUDIBLE AND VISUAL ALARMS 469 <br />IX. OWNER/OPERATOR SIGNATURE <br />1 certify that the infon anon provided herein is true and accurate to the best of my knowledge. <br />SIGNATURE OF OWNER/OPERATOR <br />DATE 470 <br />NAME OF OWNER/OPERATOR (print) <br />TITLE OF OWNER/OPERATOR <br />TERRY D. MIELSEN 471 <br />CFO 472 <br />Permit Number (For local use only) 473 Pemrit Approved (For local use only) 474 Pemut Expiration Date (For local use only) 475 <br />PT0003365 EE0003804 1/1/1993 <br />UPCF (12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.