My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2000-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:31:54 PM
Creation date
6/23/2020 6:56:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2007
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504388_1605 S EL DORADO_2000-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />n <br />SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN - PAGE 1 <br />TYPE OF ACTION 1"l 1. NEW PLAN ❑ 2. CHANGE OF INFORMATION <br />Mol. <br />PLAN TYPE .4 MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br />Moe. <br />(Check one item only) ❑ THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br />I. FACILITY INEORMATON <br />µ <br />FACILITY ID # (Agency Use Only) <br />FACILITY NAME P, M k% IV P- <br />Moa <br />FACILITY SITE ADDRESS t Q �, M04 <br />CITY CA- al <br />5. <br />II: EQUIPWNT TESTING AND PREVENTIVE MAINTENANCE <br />State law requires that testing, preventive maintenance, and calibration of mo i ing equipment (e.g., sensors, probes, line leak detectors, etc.) be performed in <br />Mob. <br />accordance with the equipment manufacturers' instructions, or annually, chever is more frequent. Such work must be performed by qualified personnel. <br />MONITORING EQUIPMENT IS SERVICED 1. ANNUALLY ❑ 99. OTHER (Specify): <br />MOT <br />II.MONITORING L.CA.TIONS <br />This monitoring plan must include a Site Plan showing the general tank and piping layouts and the locations where monitoring is performed (i.e., location of each sensor, <br />line leak detector, monitoring system control panel, etc.). If you already have a diagram (e.g., current UST Monitoring Site Plan from a Monitoring System Certification <br />form, Hazardous Materials Business Plan map, etc.) which shows all required information, include it with this plan. <br />I. v TANK 1VIONITUING , <br />MO ITORING IS PERFORMED USING THE FOLLOWING METHOD(S): (Check all that apply) <br />M10. <br />jZ 1. CONTINUOUS ELECTRONIC MONITORING 0 ANK ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT VAULT(S) <br />SECONDARY CONTAINMENT IS: a. DRY ❑ b. LIQUID FILLED ❑ c. UNDER PRESSURE ❑ d. UNDER VACUUM <br />M11. <br />PANEL MANUFACTURER: co, L 1, �-k C-0_ * M' G ' Mu. MODEL #: -T L.- S 3>`0 <br />M13 <br />LEAK SENSOR MANUFACTURER: V "! '" _�'� M14. MODEL #(S):t <br />_1 <br />M15. <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S) -C257 <br />f- <br />PANEL MANUFACTURER: M16. MODEL #: <br />MIT <br />IN -TANK PROBE MANUFACTURER: M18. MODEL #(S): <br />M19. <br />LEAK TEST FREQUENCY: ❑ a. CONTINUOUS ❑ b. DAILY/NIGHTLY ❑ c. WEEKLY <br />M20. <br />❑ d. MONTHLY ❑ e. OTHER (Specify):. M21. <br />PROGRAMMED TESTS: ❑ a. 0.1 g.p.h. ❑ b. 0.2 g.p.h. ❑ c. OTHER (Specify): M22. <br />M23. <br />❑ 3. INVENTORY RECONCILIATION ❑ a. MANUAL PER 23 CCR §2646 ❑ b. STATISTICAL PER 23 CCR §2646.1 <br />M24. <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) PER 23 CCR §2645 <br />TESTING PERIOD: ❑ a. 36 HOURS ❑ b. 60 HOURS <br />M25. <br />❑ 5. INTEGRITY TESTING PER 23 CCR §2643.1 <br />TEST FREQUENCY: ❑ a. ANNUALLY ❑ b. BIENNIALLY ❑ c. OTHER (Specify): M26. <br />M27. <br />❑ 6. VISUAL MONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY (Requires agency appmval) <br />❑ 99. OTHER (Specify): <br />M28. <br />r r E M©NIr __0- No <br />MO TORING IS PERFORMED USING THE FOLLOW METHOD(S) (Check all that apply) <br />Mao. <br />1. CONTINUOUS ELECTRONIC MONITORING PIPING SUMP(S)/fRENCH(ES) AND OTHER SECONDARY CONTAINMENT <br />SECONDARY CONTAINMENT I$; a. DRY b. LIQUID F�,LED ❑ c. UNDER PRESSURE ❑ d. UNDER VACUUM <br />M" - <br />, %i -e_ M32. MODEL #: T L_ Cf <br />PANEL MANUFACTURER: �/ <br />M33. <br />M33. <br />LEAK SENSOR MANUFACTURER: M34. MODEL #(S): r <br />T135. <br />WILL A PIPING LEAK ALARM TRIGGER AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN? a. ES ❑ b. NO <br />'""6 <br />WILL FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN?EV. YES ❑ b. NO <br />M37 - <br />3z2. <br />2.MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS <br />OFF <br />PRODUCT FLOW WHEN A LEAK IS DETECTED r G -''�f-�� (��� �� ��''�' <br />MLLD MANUFACTURER(s): g.Cb rz "��y ' " �""-' M38. MODE #( �X <br />39 <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUT)IEL PERFORMS 3.0 g.p.h. LEAK TESTS <br />ELLD MANUFACTURER: M40. MODEL #: <br />M41. <br />PROGRAMMED LINE INTEGRITY TESTS: ❑ a. MINIMUM MONTHLY 0.2 g.p.h. ❑ b. MINIMUM ANNUAL 0.1 g.p.h. <br />M42. <br />WILL ELLD DETECTION OF A PIPING LEAK TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a. YES ❑ b. NO <br />M43. <br />WILL ELLD FAILURE/DISCONNECTION TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ a. YES ❑ b. NO <br />M44. <br />❑ 4. INTEGRITY TESTING <br />TEST FREQUENCY: ❑ a. ANNUALLY ❑ b. EVERY 3 YEARS ❑ c. OTHER (Specify) Mas. <br />M46. <br />❑ 5.VISUAL MONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY* ❑ C. MIN. MONTHLY & EACH TIME SYSTEM OPERATED" <br />M47. <br />*Requires agency approval "" Allowed for monitoring of unburied emergency generator fuel piping only per HSC §25281.5(b)(3) <br />El6. PIPING IS SUCTION PIPING MEETING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR §2636(a)(3) <br />❑ 7. NO PRODUCT OR REMOTE FILL PIPING IS CONNECTED TO THE UST(s) <br />❑ 99. OTHER (Specify) <br />M48. <br />SJCEHD-d (07/03) -1/4 07/23/03 <br />N. <br />me- <br />
The URL can be used to link to this page
Your browser does not support the video tag.