Laserfiche WebLink
MONIT(f ING SYSTEM CERTIFf ATION <br />CERTIFICATION /TEST DATE: August 14, 2006 <br />Al. FACILITY <br />A2. OWNER <br />Name Miramar Enterprises <br />Name Angle Enterprises <br />Address 1605 S. EI Dorado Street, Stockton, CA 95206 <br />Address 35584 Conavan Lane, Fremont, CA 94536 <br />Phone # 209-939-1906 <br />Phone # 510-552-4822 <br />Contact Balaji Angle <br />Contact Balaji Angle <br />D. RESULTS OF TESTING / SERVICING <br />Make / Model of Monitoring System: Gilbarco EMC <br />Software Version Installed: 8.01 <br />Complete the following checklist: <br />■ Yes ❑ No* Is the audible alarm operational? <br />■ Yes ❑ No* Is the visual alarm operational? <br />■ Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br />■ Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modems) <br />■ N/A operational? <br />■ Yes ❑ No * For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ■ Sump/Trench sensors; ❑ Dispenser Containment Sensors. <br />positiveE Yes El No* Did you confirm <br />ElYes ElNo * For tank sy t ms that utilize shut -down i <br />monitoring system as the primary tank overfill device (i.e. no <br />ze the n n <br />■ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill points) and operating properly? If so, at what percent of tank capacity does the alarm trigger? <br />■ Yes * ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />■ Yes * ❑ No Was any liquid found inside any secondary containment systems designed as dry systems? <br />(Check all that apply) ❑ Product; ■ Water. If yes, describe causes in Section E, below. <br />r- <br />■ Yes ❑ No* Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />■ Yes ElNo- Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Replaced power lamp on the EMC. <br />Minor condensation in the 91 STP sump. <br />2006 Walton Engineenng, Inc. <br />Page 2 of 3 <br />