My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2008-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:37:30 PM
Creation date
6/23/2020 6:56:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2018
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0504388_1605 S EL DORADO_2008-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ys <br />T 2:92 SUPREME <br />OLIQUI'D SENSOR SETUP <br />2:VAPOR P SENSOR <br />CATEGORY VAPOR PRESSURE <br />PRODUCT CODE 2 <br />THERMAL COEFF :.000700 <br />- - - - - - - - - - - <br />s 8:ATM P SENSOR <br />TANK DIAMETER 127.50 <br />L 1:87 STP SUMP <br />CATEGORY ATM P SENSOR <br />TANK PROFILE I PT <br />TRI-STATE (SINGLE FLOAT) <br />FULL VOL 8020 <br />CATEGORY : STP SUMP <br />FLOAT SIZE: 4.0 IN. <br />L 2:92 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />WATER WARNING 20 <br />CATEGORY STP SUMP <br />HIGH WATER LIMIT: 3:0 <br />MAX OR LABEL VOL: 8020 <br />L 3:87-92 ANNULAR <br />OVERFILL LIMIT 90% <br />TRI-STATE (SINGLE FLOAT) <br />7218 <br />CATEGORY ANNULAR SPACE <br />HIGH PRODUCT 95% <br />PMC SETUP <br />7619 <br />DELIVERY LIMIT 9% <br />PMC VERSION: 01.02 <br />721 <br />VAPOR PROCESSOR TYPE <br />LOW PRODUCT 500 <br />VEEDER-ROOT POLISHER <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 25 <br />TANK TILT 0.00 <br />ANALYSIS TIMES <br />PROBE OFFSET 0.00 <br />TIME: 11:59 PM <br />DELAY MINUTES: 1 <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />OUTPUT RELAY SETUP <br />LINE MANIFOLDED TANKS <br />- - - - - - - - - - - - <br />T#: NONE <br />R 1:87 STP <br />TYPE: <br />LEAK MIN PERIODIC: 0/0 <br />STANDARD <br />0 <br />NORMALLY CLOSED <br />PERIODIC TEST TYPE <br />SOFTWARE REVISION LEVEL <br />STANDARD <br />VERSION 329.01 <br />IN-TANK ALARMS <br />SOFTWARE# 346329-100-B <br />PERIODIC TEST FAIL <br />ALL:HIGH WATER ALARM <br />CREATED - 09.01.29.15.44 <br />ALARM DISABLED <br />ALL:LOW PRODUCT ALARM <br />NO SOFTWARE MODULE <br />GROSS TEST FAIL <br />LIQUID SENSOR ALMS <br />SYSTEM FEATURES: <br />ALARM DISABLED <br />L I:FUEL ALARM <br />PERIODIC IN-TANK TESTS <br />L 1:SENSOR OUT ALARM <br />ANNUAL IN-TANK TESTS <br />PER TEST AVERAGING: OFF <br />L 2:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />TANK TEST NOTIFY: OFF <br />L 2:SHORT ALARM <br />TNK TST SIPHON BREAKOFF <br />PMC ALARMS <br />VP EMISSIONS FAIL <br />DELIVERY DELAY I MIN <br />VP PRESSURE FAIL <br />PUMP THRESHOLD 10.00% <br />R 2:92 STP <br />TYPE: <br />STANDARD <br />ALARM HISTORY REPORT <br />NORMALLY CLOSED <br />----- SENSOR ALARM ----- <br />L 1:87 STP SUMP <br />IN-TANK ALARMS <br />STP SUMP <br />ALL:HIGH WATER ALARM <br />FUEL ALARM <br />ALL:LOW PRODUCT ALARM <br />NOV 6, 2013 2:47 PM <br />LIQUID SENSOR ALMS <br />SETUP DATA WARNING <br />L 2:FUEL ALARM <br />NOV 6, 2013 2:43 PM <br />LEAK TEST METHOD <br />L I:SENSOR OUT ALARM <br />- - - - - - - - - - - - <br />L 2:SENSOR OUT ALARM <br />TEST ON DATE : ALL TANK <br />L I:SHORT ALARM <br />SEP 29, 1999 <br />L 2:SHORT ALARM <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />PMC ALARMS <br />DURATION 2 HOURS <br />VP EMISSIONS FAIL <br />VP PRESSURE FAIL <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />END <br />NORMAL <br />SMARTSENSOR SETUP <br />- - - - - - - - - - - <br />- <br />1:VR CANISTER <br />CATEGORY VAPOR VALVE <br />
The URL can be used to link to this page
Your browser does not support the video tag.