Laserfiche WebLink
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> 01 <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B �` y; <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ' <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT S CHANGE OF INFORMATION 7 PER�,7 <br /> SITE TEMPORARY TANK CLOSURE ❑ 8 TAN <br /> DBA OR FACILITY NAME WHE <br /> RE TANK IS INSTALLED: y <br /> I. TANK DESCRIPTIONCOMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.D.III <br /> B. MANUFACTURED BY: <br /> C. OATE INSTALLED(MO/DAY/YEAR) <br /> _ D. TANK CAPACITY IN GALLONS: <br /> Ii.TANK CONTENTS IF A•1 IS MARKED,COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. Cto REGULAR 3 DIESEL <br /> UNLEADED❑ 2 PETROLEUM ❑ 80 EMPTY � 4 GASANOL <br /> 1 PRODUCT Q lb PREMIUM L�Jj ❑ 6 AVIATION GAS <br /> ❑ ❑3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE UNLEADED 5 JET FUEL 7 METHANOL <br /> ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW} <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.0: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.13,AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER <br /> SYSTEM <br /> ❑ 95 UNKNOWN <br /> ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> 1 <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ff7 ALUMINUM # <br /> ❑ 8 100% METHANOL COMPATIBLE WlFRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> i <br /> ❑ t RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING 4 PHENOLIC LINING <br /> C.INTERIOR PV 5 GLASS LINING ❑ 6 UNLINED ' <br /> LINING ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP {{ <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 4 FIBERGLASS REINFORCED PLASTIC ! <br /> ❑95 UNKNOWN 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) <br /> OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE ) <br /> i <br /> A. SYSTEM TYPE A U 1 SUCTION U PRESSURE A U 3 GRAVITY <br /> A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL U 2 DOUBLE WALL A U 3 LINED TRENCH <br /> A U 9t <br /> N A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) ERGLASS PIPE <br /> CORROSION A U S ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING <br /> PROTECTION A U 9 GALVANIZED STEEL A (J 10 CATHODIC PROTECTION 0°6 METHANOL COMPATIBLE W/FRP <br /> A U 95 UNKNOWN THER <br /> D. LEAK DETECTION 1 AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING s <br /> MONITORIN9 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK �2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING 7 INTERSTITIAL MONITORING a 91 NONE <br /> a 95 UNKNOWN a 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF <br /> SUBSTANCE REMAINING 3.WAS TANK FILLED WITH <br /> GALLONS INERTMATERIAL? YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE I.D.# COUNTY# JURISDICTION# FACILITY# TANK# <br /> PERMIT NUMBER PERMIT APPROVED L BYIDATE / <br /> PERMIT EXPIgATION DATE ' <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORMA,UNLESS A CURRENT FO HAS BEEN FILED. <br /> FILE THIS FORM WITH�,�LOCA IMPLEMENTING THE UNDERGROUND STORAGE TA GULATIONS G� <br /> FORM 8 (72.91) <br /> i { <br /> FOROM48•RS <br />