My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2005-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 1:40:04 PM
Creation date
6/23/2020 6:56:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2007
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2005-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
348
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Adh <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> TEST DATE:05/31/07 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER2 2 4 9 4 3 2 <br /> CLIENT:FLYING "J" INC AUSTIN,TEXAS 78759(512)451-6334 SITE:FLYING J 0500075 <br /> Tank ID: DSLl 1 Tank manifolded: YES Bottom to top fill in inches: 92.0 <br /> Product: DIESEL Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 15,000 Vapor recovery manifolded: No Fill pipe length in inches: <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 484 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> DSL 1 RUNS AUTO AND RV DIESEL LINES AND 19-20. <br /> 1 MAIN LINE AND 4 SATTELITE LINES <br /> Dipped Water Level: Start(in) End(in) New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: FXl-DV FXl-DV <br /> Test time: S/N: 5103 10704 0233 <br /> Inclinometer reading: Open time in sec: 9.00 <br /> Holding psi: 34 <br /> VacuTect Test Type: NOT Resiliency psi: <br /> 274 NOT <br /> VacuTect Probe Entry Point: TESTED <br /> Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 10 <br /> Tank water level in inches: Calib. leak in gph: 3.00 3.00 <br /> Water table depth in inches: Results: PASS FAIL <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> Material: DW FIBERG DW FIBERG DW FIBERG DW FIBERG <br /> Diameter(in): 3.0 3.0 3.0 3.0 <br /> Length (ft): 250.0 15.0 15.0 15.0 <br /> Test psi: 75 75 75 75 <br /> Bleedback cc: 280 280 280 280 <br /> Test time(min): 30 30 30 30 <br /> Start time: 14:15 14:15 14:15 14:15 <br /> End time: 14:45 14:45 14:45 14:45 <br /> Final gph: 0.003 0.003 0.003 0.003 <br /> Result: PASS PASS PASS PASS <br /> Pump type: PRESSURE NONE NONE NONE <br /> Pump make: RED JACKET GILBARCO GILBARCO GILBARCO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 06/25/2007 08:52 <br />
The URL can be used to link to this page
Your browser does not support the video tag.