Laserfiche WebLink
D. Results of Testing/Servicing <br />Software Version Installed: 317.02 <br />rmmnlete the following checklist: <br />C Yes <br />❑ No' <br />Is the audible alarm operational? <br />x, Yes <br />❑ No' <br />Is the visual alarm operational? <br />' Yes <br />❑ No" <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />z Yes <br />❑ No` <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br />proper operation? <br />Yes <br />❑ No` <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? <br />[I N/A <br />k] Yes <br />❑ No' <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br />❑i N/A <br />detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut -down? (Check all that apply) <br />[BSump/Trench Sensors; El Dispenser Containment Sensors. Did you confirm positive shut -down due to leaks and sensor <br />failure/disconnection? BYeS; ®No. <br />❑ Yes <br />❑ No` <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention <br />N/A <br />valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent <br />of tank capacity does the alarm trigger? % <br />Yes' <br />❑ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes` <br />pe -1 No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) I]i Product; pWater. If <br />es, describe causes in Section E, below. <br />KI Yes <br />1-1 No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />*i Yes <br />❑ No' <br />Is all monitoring equipment operational per manufacturer's specifications? <br />In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />Liquid sensor in auto Diesel STP sump did not alarm or shut -down turbine. Installed new sensor tested and <br />passed. <br />Monitoring System Certification Page of 12/07 <br />