Laserfiche WebLink
FILE COPY <br /> San Joa uin Count <br /> Joaquin Y <br /> "WN..P11 Environmental Health Department DIRECTOR <br /> �•' = � •n Linda Turkatte,REHS <br /> z =y 1868 East Hazelton Avenue <br /> U): s. { Stockton, California 95205-6232 PROGRAM Robert McCCOORDINATORS RINA ORS <br /> D <br /> Jeff Carruesco,REHS,RDI <br /> Cq •.,,,,..` �P Website: www.sjgov.org/ehd Kasey Foley,REHS <br /> Rodney Estrada,REHS <br /> Phone: (209)468-3420 Adrienne Ellsaesser, REHS <br /> Fax: (209)464-0138 <br /> January 14, 2015 <br /> JONES COVEY GROUP INC <br /> 9595 LUCAS RANCH ROAD#100 <br /> RANCHO CUCAMONGA, CA 91730 <br /> Re: FLYING J TRAVEL PLAZA#618, SR0071256 <br /> 1501 N JACK TONE RD <br /> RIPON,CA 95366 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to replace the damaged dispenser #25 (Gilbarco Encore 500S <br /> like-for-like) on the underground storage tank (UST) system at the above noted address. The <br /> permit has been approved with the following conditions: <br /> 1. Contact. the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Elena Manzo at (209) 953-7699 to arrange the following inspection <br /> appointment (a 48-hour notice is required for inspection appointments). <br /> a. 24-hour hydrostatic test (or equivalent) on under dispenser containment sump (UDC) <br /> UDC#25 <br /> b: Verification of the dispenser footprint contained by the UDC <br /> c. Visual inspection of the piping within the dispenser <br /> Please be aware that the facility cannot operate the aforementioned dispenser <br /> system prior to the EHD inspection and approval. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of. several permissible valid, current contractor's licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid; current California UST Service Technician certificate issued by the <br /> International Code Council (ICC), and <br /> c. A valid, current certificate of training from the manufacturer(s) of the component(s) <br /> being tested, repaired, or serviced. <br /> 5. Qualified installers must possess or work under the direct and personal supervision of an <br /> individual physically present at the work site who possesses all of the following: <br />