My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2014-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2021 4:36:01 PM
Creation date
6/23/2020 6:57:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2015
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2014-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> RECEIVED <br /> SWRCB,January 2002 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTINGS E P 1 <br /> Test Method Developed By: ❑UDC Manufacturer X Industry StandaProfessional En ineer <br /> ❑Other(Specify) 9NVIR7a) TL LT <br /> Test Method Used: ❑Pressure I❑Vacuum <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002 <br /> UDC# 30 Sat UDC# 30 Main UDC# UDC# <br /> UDC Manufacturer: Unknown Unknown <br /> UDC Material: Fiberglass Fiberglass <br /> UDC Depth: 30" 30" <br /> Height from UDC Bottom to Top 13" 14" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 91. 10" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Dry Dry <br /> Portion of UDC Tested' 17" 18" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes []No X NA ❑Yes ❑No 91 NA ❑Yes ❑No K NA ❑Yes ❑No 9 NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown?* ❑Yes ❑No Gd NA F1 Yes LlNo K NA 7 Yes ❑No ®NA ❑Yes ❑No ©NA <br /> Was fail-safe verified to be <br /> ❑ <br /> o erational? F1Yes No KNA I I Yes F1No X NA Ll Yes 1-1No XI NA C]Yes F.]No CNA <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: 4:48 prn 1 5:04 prn 4:48 prn 5:04 prn <br /> Initial Reading(Ri): 5.6957" 5.6955" 3.9527" 3.9518" <br /> Test End Time: 5:03 pm 5:19 prn 5:03 pm 5:19 pm <br /> Final Reading(RF): 5.6955" 5.6955" 3.9513" 3.9514" <br /> Test Duration: 15 Minutes Each 30 15 Minutes Each (30 <br /> Change in Reading(RF-RI): -0.0002 1 0.0000 -0.0014 -0.0004 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" /-0.002" <br /> Test Result: ® Pass ❑Fail ® Pass ❑Fail ® Pass ❑Fail ® Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No X NA X Yes ❑No ❑NA X Yes ❑No ❑NA ®Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> ® <br /> verified functional after testing? <br /> Yes []No11NA ®Yes ❑No ❑NA Yes Ll No ❑NA ©Yes I]No 11 NA <br /> Comments—(include information on repairs made prior to testing, and recommended folloiv-up for failed tests) <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.